Abstract
This paper analyzes the presence of undesired quantization-induced perturbations (QIP) in a dc-dc buck-boost converter using a two-loop digital current control. This work introduces design conditions regarding control laws gains and signal quantization to avoid the quantization effects due to the addition of the outer voltage loop in a digital current controlled converter. The two-loop controller is composed of a multisampled average current control (MACC) in the inner current-programmed loop and a proportional-integrator compensator at the external loop. QIP conditions have been evaluated through simulations and experiments using a digitally controlled pulse width modulation (DPWM) buck-boost converter. A 400 V 1.6 kW proof-of-concept converter has been used to illustrate the presence of QIP and verify the design conditions. The controller is programmed in a digital signal controller (DSC) TMS320F28377S with a DPWM with 8.96-bit equivalent resolution, a 12-bit ADC for current sampling, and a 12-bit ADC for voltage sampling or a 16-bit ADC for voltage error sampling.
Funder
European Regional Development Fund
SERC
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献