Author:
Kumchai Hattanas,Juntavee Patrapan,Sun Arthur F.,Nathanson Dan
Abstract
Background: A variety of veneering options to zirconia frameworks are now available. The purpose of this study is to evaluate the effect of veneer materials, veneering methods, cement materials, and aging on the failure load of bilayered veneer zirconia. Material and methods: Zirconia bars (20 × 4 × 1 mm) were veneered to 2 mm total thickness (n = 10/group). Veneering method groups included: 1. Hand-layered feldsparthic porcelain (VM = Vita VM9, Vident) and fluorapatite glass–ceramic (CR = IPS e.max Ceram, IvoclarVivadent); 2. Pressed feldspathic porcelain (PM = Vita PM9, Vident) and fluorapatite glass–ceramic (ZP = IPS e.max ZirPress, IvoclarVivadent); 3. CAD-/CAM-milled feldspathic ceramic (TF = Vitablocs Triluxe Forte, Vident) and lithium-disilicate glass–ceramic (CAD = IPS e.max CAD, IvoclarVivadent). CAD/CAM veneers were either cemented with resin cements (P = Panavia21, KurarayDental), (R = RelyX Ultimate, 3M ESPE), (M = Multilink Automix, Ivoclar Vivadent) or fused with fusion glass–ceramic (C = CrystalConnect, IvoclarVivadent). A three-point bending test (15 mm span, zirconia on tension side) was performed on Instron universal testing machine (ISO 6872) recording load-to-failure (LTF) of first veneer cracks or catastrophic failure. For group VM, PM, TF-M, TF-C, CAD-M, CAD-C, ten more bars were prepared and aged with cyclic loading (100,000 cycles, 50% LTF) and thermocycling (2000 cycles) before testing. Data were analyzed by ANOVA, Tukey HSD post hoc tests, and t-test (α = 0.05). Zirconia veneered with IPS e.max CAD by fusing had significantly higher failure load compared with zirconia veneered with other veneering materials (p ≤ 0.05). For cemented veneers, the cement type had a significant effect on the failure load of the veneer zirconia specimens. Specimens cemented with Panavia 21 had a lower resistance to loading than other cements. The aging experiment revealed a significant difference in failure load between non-aged and aged bars in groups VM and PM, but not in the groups with CAD-/CAM-milled veneers. In conclusion, veneer materials, veneering methods, and cement materials have a significant effect on the failure load of bilayered veneer zirconia. CAD-/CAM-milled veneer zirconia is not susceptible to aging performed in this study.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献