TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring
Author:
Jiang Xikang1ORCID, Zhang Jinhui2, Mu Wenyao1, Wang Kun2, Li Lei1ORCID, Zhang Lin1
Affiliation:
1. School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China 2. Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China
Abstract
Contactless continuous blood pressure (BP) monitoring is of great significance for daily healthcare. Radar-based continuous monitoring methods typically extract time-domain features manually such as pulse transit time (PTT) to calculate the BP. However, breathing and slight body movements usually distort the features extracted from pulse-wave signals, especially in long-term continuous monitoring, and manually extracted features may have limited performance for BP estimation. This article proposes a Transformer network for Radar-based Contactless Continuous Blood Pressure monitoring (TRCCBP). A heartbeat signal-guided single-beat pulse wave extraction method is designed to obtain pure pulse-wave signals. A transformer network-based blood pressure estimation network is proposed to estimate BP, which utilizes convolutional layers with different scales, a gated recurrent unit (GRU) to capture time-dependence in continuous radar signal and multi-head attention modules to capture deep temporal domain characteristics. A radar signal dataset captured in an indoor environment containing 31 persons and a real medical situation containing five persons is set up to evaluate the performance of TRCCBP. Compared with the state-of-the-art method, the average accuracy of diastolic blood pressure (DBP) and systolic blood pressure (SBP) is 4.49 mmHg and 4.73 mmHg, improved by 12.36 mmHg and 8.80 mmHg, respectively. The proposed TRCCBP source codes and radar signal dataset have been made open-source online for further research.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference21 articles.
1. Man, P.K., Cheung, K.L., Sangsiri, N., Shek, W.J., Wong, K.L., Chin, J.W., Chan, T.T., and So, R.H.Y. (2022). Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring. Healthcare, 10. 2. Al Fahoum, A.S., Abu Al-Haija, A.O., and Alshraideh, H.A. (2023). Identification of Coronary Artery Diseases Using Photoplethysmography Signals and Practical Feature Selection Process. Bioengineering, 10. 3. Arrhythmia detection and classification using ECG and PPG techniques: A review;Neha;Phys. Eng. Sci. Med.,2021 4. Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time;Ganti;IEEE J. Biomed. Health Inform.,2021 5. Herranz Olazabal, J., Wieringa, F., Hermeling, E., and Van Hoof, C. (2023). Comparing Remote Speckle Plethysmography and Finger-Clip Photoplethysmography with Non-Invasive Finger Arterial Pressure Pulse Waves, Regarding Morphology and Arrival Time. Bioengineering, 10.
|
|