Affiliation:
1. Department of Orthodontics and Dentofacial Orthopedics, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki 852-8588, Japan
Abstract
Background: Temporary anchorage devices (TADs) are broadly used in orthodontic treatment. TADs must be placed accurately to avoid collision against tooth roots. To place miniscrews with a higher accuracy, a digitally designed surgical guide was proposed in previous studies. However, to our knowledge, there have been no articles that have assessed the minimal required length to achieve good drilling accuracy. The objective of the present study was to evaluate the accuracy of pre-drilling using computer-aided designed surgical guides with different lengths. Methods: A typodont model was scanned, and surgical guides of 3.0, 4.5, and 6.0 mm were designed. Duplicated typodonts and the surgical guides were printed with a 3D printer. Using these models and surgical guides, pre-drillings were performed. Freehand drilling was also conducted for the control. The drilled models were scanned with micro-computed tomography to evaluate the accuracy. Results: The mean errors at the tip of the drill were 0.44 mm, 0.61 mm, 0.41 mm, and 0.24 mm for the freehand drilling, and 3.0, 4.5, and 6.0 mm for the surgical guide, respectively. Conclusion: The results suggested that a longer surgical guide was recommended to achieve good insertion accuracy for a narrow interradicular space, and that 3.0 mm was enough when an error of 1.0 mm was acceptable for the insertion site.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference17 articles.
1. Orthodontic Miniscrew Failure Rate and Root Proximity, Insertion Angle, Bone Contact Length, and Bone Density;Watanabe;Orthod. Craniofac. Res.,2013
2. Root Proximity Is a Major Factor for Screw Failure in Orthodontic Anchorage;Kuroda;Am. J. Orthod. Dentofac. Orthop.,2007
3. Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading;Shan;J. Craniofacial Surg.,2015
4. Inchingolo, A.M., Malcangi, G., Costa, S., Fatone, M.C., Avantario, P., Campanelli, M., Piras, F., Patano, A., Ferrara, I., and Di Pede, C. (2023). Tooth Complications after Orthodontic Miniscrews Insertion. Int. J. Environ. Res. Public Health, 20.
5. Accurate Pre-Surgical Determination for Self-Drilling Miniscrew Implant Placement Using Surgical Guides and Cone-Beam Computed Tomography;Miyazawa;Eur. J. Orthod.,2010