Development of Robust PEBAX-Based Angiographic Catheter: Design and In Vitro Study

Author:

Inam Hafsa1ORCID,Ali Murtaza Najabat1,Jameel Ibraheem Raza2,Awaiz Dil2,Qureshi Zunaira3

Affiliation:

1. Biomedical Engineering and Sciences Department, School of Mechanical and Manufacturing Engineering (SMME), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan

2. N-ovative Health Technologies, NHT, National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan

3. Medical Devices Development Center (MDDC), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan

Abstract

Background: Keeping in mind the unceasingly escalating prevalence of coronary disease worldwide, the mortality rate is also expected to rise with a staggering increase in healthcare costs. Angiography is the gold standard for diagnosing these blockages that trigger these diseases. Amides and urethanes are the common catheter construction material used for angiography. However, the experimental evidence verifying the use of PEBAX® and comparing its performance with that of commercially available catheters for angiography is not published despite it being well recognized for its excellent flexural modulus, mechanical properties, and biocompatibility and its potential to reduce the incidence of vascular spasm during intravascular diagnostic and interventional procedures. Therefore, the aim of this study was to develop a PEBAX®-based angiographic catheter and evaluate its performance in comparison with three commercially available nylon- and polyurethane-based angiographic catheters. Methodology: A PEBAX®-based angiographic catheter was developed for this purpose. This study analyzes and reports the performance and behavior of PEBAX®-, nylon-, and polyurethane-based catheters. The catheter’s performance and arterial forces’ endurance nature were mapped out by evaluating pushability (advancement force) and selective bench tests outlined in the applicable regulatory standard. Conclusions: The PEBAX®-based catheter exhibited the least bond-flexural rigidity (180.4 g), which was approximately one-third of that shown by all six French catheters and which exhibited the least advancement force (510.4 g), which was approximately 50% less than that of the nylon- and polyurethane-based catheters when traversing through the mock arterial system. Bench testing was carried out as per the applicable regulatory standard; the differences obtained between individual catheters were discussed in detail. Based on this extensive in vitro assessment, it was concluded that the PEBAX®-based catheters outperformed the nylon- and polyurethane-based catheters, exhibiting an exceptionally minimal advancement force of 510.4 g. This leads to the inference that this catheter can inject more radiopaque material (because of the enhanced flow rate) to the coronary arteries and can play a significant role in minimizing vascular spasms during a diagnostic procedure.

Publisher

MDPI AG

Reference39 articles.

1. World Health Organization: WHO (2024, August 19). Cardiovascular Diseases (CVDs). (11 June 2021), Available online: https://www.who.int/news-room/fact-sheets/detail/cardiovascular-diseases-(cvds).

2. Trackability, crossability, and pushability of coronary stent systems-an experimental approach;Schmidt;Biomed. Tech. Biomed. Eng.,2002

3. Brinza, C., Floria, M., Popa, I., and Burlacu, A. (2022). The Prognostic Performance of Ferritin in Patients with Acute Myocardial Infarction: A Systematic Review. Diagnostics, 12.

4. Plaque rupture with severe pre-existing stenosis precipitating coronary thrombosis. Characteristics of coronary atherosclerotic plaques underlying fatal occlusive thrombi;Falk;Br. Heart J.,1983

5. Role of thrombus in plaque formation in the human diseased coronary artery;Friedman;Br. J. Exp. Pathol.,1966

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3