Affiliation:
1. Department of Neurosurgery, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou 215006, China
2. Department of Neurosurgery & Brain and Nerve Research Laboratory, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou 215006, China
Abstract
Background: As essential techniques, intraoperative indocyanine green video angiography (ICG-VA) and FLOW 800 have been widely used in microsurgery for arteriovenous malformations (AVMs). In the present report, we introduced a supplementary technical trick for judging the degree of lesion resection when there were superficial drainage veins. FLOW 800 analysis is used to verify our conjecture. Methods: A retrospective analysis of a 33 case cohort treated surgically from June 2020 to September 2022 was conducted and their lesions were removed by superficial drainage veins as a supplementary technical trick and analyzed with FLOW800. Results: In our 33 AVMs, the feeding artery was visualized earlier than the draining vein. Intraoperatively, the T1/2 peak and slope of the draining vein were significantly higher than that of the lesion. However, the maximum fluorescence intensity (MFI) of the draining vein decreased as the procedure progressed (p < 0.001). After reducing the blood flow to the nidus by progressive dissection of the feeding artery, the arteriovenous transit time (AVTT) decreased from 0.64 ± 0.47 s, was prolonged to 2.38 ± 0.52 (p < 0.001), and the MFI and slope of the nidus decreased from the pre-resection 435.42 ± 43.90 AI and 139.77 ± 27.55 AI/s, and decreased to 386.70 ± 48.17 AI and 116.12 ± 17.46 AI/s (p < 0.001). After resection of the nidus, the T1/2 peak of the draining vein increased from 21.42 ± 4.70 s, prolonged to after dissection of the blood feeding artery, 23.07 ± 5.29 s (p = 0.424), and after resection of the lesion, 25.13 ± 5.46 s (p = 0.016), with a slope from 135.79 ± 28.17 AI/s increased to 210.86 ± 59.67 AI/s (p < 0.001). Conclusions: ICG-VA integrated with FLOW 800 is an available method for determining the velocity of superficial drainage veins. Whether the color of the superficial drainage veins on the cortical surface returns to normal can determine whether the lesion is completely resected and can reduce the possibility of residual postoperative lesions.
Funder
Medical and Health Science and Technology Innovation Project of the Suzhou Health Commission
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献