Variations in Values of State, Response Entropy and Haemodynamic Parameters Associated with Development of Different Epileptiform Patterns during Volatile Induction of General Anaesthesia with Two Different Anaesthetic Regimens Using Sevoflurane in Comparison with Intravenous Induct: A Comparative Study

Author:

Stasiowski MichałORCID,Duława Anna,Szumera Izabela,Marciniak RadosławORCID,Niewiadomska EwaORCID,Kaspera Wojciech,Krawczyk Lech,Ładziński Piotr,Grabarek BeniaminORCID,Jałowiecki Przemysław

Abstract

Background and Objectives: Raw electroencephalographic (EEG) signals are rarely used to monitor the depth of volatile induction of general anaesthesia (VIGA) with sevoflurane, even though EEG-based indices may show aberrant values. We aimed to identify whether response (RE) and state entropy (SE) variations reliably reflect the actual depth of general anaesthesia in the presence of different types of epileptiform patterns (EPs) in EEGs during induction of general anaesthesia. Materials and Methods: A randomized, prospective clinical study was performed with 60 patients receiving VIGA using sevoflurane with the increasing concentrations (group VIMA) or the vital capacity (group VCRII) technique or an intravenous single dose of propofol (group PROP). Facial electromyography (fEMG), fraction of inspired sevoflurane (FiAA), fraction of expired sevoflurane (FeAA), minimal alveolar concentration (MAC) of sevoflurane, RE and SE, and standard electroencephalographic evaluations were performed in these patients. Results: In contrast to periodic epileptiform discharges, erroneous SE and RE values in the patients’ EEGs were associated with the presence of polyspikes (PS) and rhythmic polyspikes (PSR), which were more likely to indicate toxic depth rather than false emergence from anaesthesia with no changes in the FiAA, FeAA, and MAC of sevoflurane. Conclusion: Calculated RE and SE values may be misleading during VIGA when EPs are present in patients’ EEGs. During VIGA with sevoflurane, we recommend monitoring raw EEG data in scientific studies to correlate it with potentially erroneous RE and SE values and the end-tidal concentration of sevoflurane in everyday clinical practice, when monitoring raw EEG is not available, because they can mislead anaesthesiologists to reduce sevoflurane levels in the ventilation gas and result in unintentional true emergence from anaesthesia. Further studies are required to investigate the behaviour of EEG-based indices during rapid changes in sevoflurane concentrations at different stages of VIGA and the influence of polyspikes and rhythmic polyspikes on the transformation of EEG signals into a digital form.

Publisher

MDPI AG

Subject

General Neuroscience

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3