Characterization of Nile Red as a Tracer for Laser-Induced Fluorescence Spectroscopy of Gasoline and Kerosene and Their Mixture with Biofuels

Author:

Koegl Matthias,Mull Christopher,Baderschneider Kevin,Wislicenus Jan,Will StefanORCID,Zigan Lars

Abstract

Suitable fluorescence tracers (“dyes”) are needed for the planar measurement of droplet sizes by using a combination of laser-induced fluorescence (LIF) and Mie scattering. Currently, no suitable tracers have been characterized for application in planar droplet sizing in gasoline and kerosene fuels, as well as biofuel blends. One promising tracer is nile red, which belongs to the fluorophore group. For its utilization for droplet size measurements, preliminary characterization of the fluorescence of the respective fuel tracer mixtures are mandatory. For this purpose, the fluorescence and absorption behavior of nile red dissolved in the surrogate fuels Toliso and Jet A-1 as well as in biofuel blends was investigated. The fluorescence signal for nile red that was dissolved in the two base fuels Toliso and Jet A-1 showed a linear behavior as a function of dye concentration. The temperature effect on spectral absorption and emission of nile red was investigated in a specially designed test cell. An ethanol admixture to Toliso led to a spectral shift towards higher wavelengths. The absorption and emission bands were shifted towards lower wavelengths with increasing temperature for all fuels. Both absorption and fluorescence decreased with increasing temperature for all fuels, except for E20, which showed an increased fluorescence signal with increasing temperature. Jet A-1 and its blends with hydroprocessed esters and fatty acids (HEFA) and farnesane did not exhibit explicit variations in spectral absorption or emission, but these blends showed a more distinct temperature dependence compared to the Toliso-ethanol-blends. The effect of photo-dissociation of the LIF signal of the fuel tracer mixtures was studied, and all fuel mixtures besides Toliso showed a more or less distinct decay in the fluorescence signal with time. In summary, all investigated fuel-tracer mixtures are suitable for LIF/Mie ratio droplet sizing in combination with nile red at moderate temperatures and low evaporation cooling rates.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3