Enhancing Antimicrobial Performance of Gauze via Modification by Ag-Loaded Polydopamine Submicron Particles

Author:

Cui Junnan1,Shu Haobo1,Zhu Panpan1,Cao Zhimin2,Wang Shuilin2,Cao Pan1

Affiliation:

1. School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China

2. Institute of Intelligent Manufacturing and Smart Transportation, Suzhou City University, Suzhou 215104, China

Abstract

Silver nanoparticles (AgNPs) are known for their antibacterial properties and their ability to promote wound healing. By incorporating silver nanoparticles into medical gauze, the resulting composite material shows promise as an advanced wound dressing. However, clinical applications are hindered by challenges related to the stability of silver nanoparticle loading on the gauze as nanoparticle leaching can compromise antibacterial efficacy. In this study, silver nanoparticles were immobilized onto polydopamine (PDA) submicron particles, which were then used to modify medical gauze. Energy dispersive spectroscopy (EDS) was employed to analyze the elemental distribution on the modified gauze, confirming successful surface modification. The antibacterial properties of the modified gauze were assessed using a laser scanning confocal microscope (CLSM). The results demonstrated a significant reduction in the adhesion rates of Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) by 99.1% and 63%, respectively, on the PDA–Ag-modified gauze. Optical density (OD) measurements at 590 nm indicated that the modified gauze effectively inhibited biofilm formation, underscoring its potent antimicrobial capabilities. Further antibacterial efficacy was evaluated by diluting and plating co-cultured bacterial solutions with the modified dressing, followed by 24 h incubation and colony counting. The gauze exhibited an antibacterial efficiency of 99.99% against E. coli and 99.8% against S. aureus. Additionally, cell compatibility tests, involving the co-culture of PDA–Ag composites with human cells, demonstrated excellent biocompatibility. These findings suggest that PDA–Ag-modified medical gauze holds significant potential for the treatment of infected wounds, offering a promising solution to improve wound care through enhanced antimicrobial activity and biocompatibility.

Funder

Industry–University Cooperation Collaborative Education Project of the Ministry of Education

Yangzhou University

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3