Abstract
The impact of the stray inductances originated from interconnects in power electronics becomes crucial with the next generation of SiC devices. This paper shows that the existing layout of a railway inverter, operating with Si IGBTs already exhibits a dynamic current imbalance between paralleled modules. This will not allow using this geometry with SiC MOSFETs. A complete investigation of the electromagnetic origin of this issue has been performed. A generic circuit model has been proposed to establish a cabling rule to design a Gate Distribution Printed Circuit Board (PCB) in such a way that it compensates the power dissymmetry. An optimization strategy has been used to obtain a new geometry of this PCB, which has been validated with a time domain simulation.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献