High−Accuracy Film−Integrated Optical Sensor for Real−Time Intraocular Pressure Monitoring

Author:

Xu Xiaobin1,Liu Zixuan1,Wang Liqiang2,Huang Yifei2ORCID,Yang He1

Affiliation:

1. School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China

2. Department of Ophthalmology, Chinese PLA General Hospital, Medical School of Chinese PLA, Beijing 100853, China

Abstract

Intraocular pressure (IOP) is a key indicator to evaluate the risk and status of glaucoma, which is one of the main causes of irreversible blindness. However, the IOP value is susceptible to circadian changes and is difficult to be measured real−time. In this paper, we designed a thin−film integrated optical IOP sensor based on the interferometry principle, which could read out the IOP value by interference patterns and monitor the value changes real−time at the same time. The theoretical and experimental results indicated that our sensor exhibited a sensitivity of 0.19 μm/mmHg and an average accuracy of 0.84 mmHg over the pressure range of 0–45 mmHg, which is comparable with the other reported optical systems but with the advantage of easier fabrication process and low−cost. Our sensor device implies great potential in the application of human physiological index measurement and other chip−integrated medical sensing instruments.

Funder

Fundamental Research Funds for the Central Universities

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

Reference26 articles.

1. Global causes of blindness and distance vision impairment 1990–2020: A systematic review and meta−analysis;Flaxman;Lancet Glob. Health,2017

2. Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta−analysis;Tham;Ophthalmology,2014

3. Risk factors for visual field progression in treated glaucoma;Juthani;Arch. Ophthalmol.,2011

4. Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial;Bengtsson;Ophthalmology,2007

5. Application progress of tonometer in clinic;Wang;Chin. J. Mod. Nurs.,2017