A Cross-Over Randomized Controlled Clinical Trial for Evaluation of Two Hygiene Protocols on Microbial Load, Tissue Health, and Opinion of Ocular Prosthesis Wearers

Author:

Makrakis Laís Ranieti1,Ribeiro Adriana Barbosa1ORCID,Evelin Letícia de Sá1,Oliveira Viviane de Cássia1ORCID,Macedo Ana Paula1ORCID,Watanabe Evandro1ORCID,Silva-Lovato Cláudia Helena1ORCID

Affiliation:

1. Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto 14040-904, Brazil

Abstract

The recommendations for the wear and hygiene of ocular prostheses can vary among practitioners, and it is still a controversial theme in the literature. This clinical trial evaluated the microbial load, tissue health of the socket, and the participants’ opinions before and after the use of two hygiene protocols. Thirty ocular prosthesis wearers used either a Daily Protocol (DPt: hygiene once a day) or Weekly Protocol (WPt: hygiene once a week) for 5 weeks with a washout of 7 days. The microbial load was quantified by the colony-forming unit count of the aerobic bacteria, Candida spp., Staphylococcus spp., and Gram-negative bacteria. The tissue health of the socket was evaluated by scores, and patients’ opinion of the protocols was evaluated using the analogic visual scale (VAS). Data were analyzed by ANOVA Repeated Measures, Friedman, Cochran’s Q Test, Wilcoxon, Fisher, and Pearson’s chi-square tests considering p < 0.05. There was no difference in the microbial load of the microorganisms (p > 0.05). Both protocols improved socket inflammation (p = 0.005) and discharge (p < 0.001); DPt improved edema (p = 0.021) and crusting (p = 0.020). There was no difference in patients’ rating responses (VAS) for all the questions of patients’ opinion (Q1: p = 1.0; Q2: p = 1.0; Q3: p = 1.0; Q4: p = 1.0; Q5: p = 1.0; Q6: p = 0.317; Q7: p = 1.0; Q8: p = 0.159). There was a correlation between eye drops/edema (p = 0.030), eye drops/pain (p = 0.016), microbial load with discharge, inflammation, eyelid edema, and pain. Inflammation was correlated with edema at baseline (p < 0.001) and after DPt (p = 0.018), and with crusting at baseline (p = 0.003); edema was correlated with crusting at baseline (p < 0.001); crusting was correlated with discharge after WPt (p < 0.001). The protocols showed no effects on the microbial load of the anophthalmic socket and ocular prosthesis. However, better tissue health and patient acceptance were observed after both regimens.

Funder

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior–Brazil

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3