Abstract
It is well known that the use of slotted stators in motors produces undesirable effects, such as magnetic flux distortion, additional losses, ripple torque, and vibration. However, a large number of studies pay more attention to stator slots and magnetic slot wedges (MSW) in asynchronous motors and permanent magnet motors, ignoring the same problems in large capacity high voltage line start permanent magnet synchronous motors (HVLSPMSM). In order to disclose the effect of the stator slot on HVLSPMSMs, the no-load air gap magnetic field distribution and stator leakage reactance are studied. Meanwhile, the differences in the starting torque, pull-in torque and pull-out torque of four slot models are compared, and the starting performance is more affected by stator slot. In practical manufacturing, the application of MSWs is the main way to change the electromagnetic performance of stator slots, so the influence of MSWs under different permeabilities on the performance of HVLSPMSMs is investigated. Finally, the effect of a stator slot on the motor starting performance and the rated performance are verified by prototypes and experimental tests, which provide a reference for the application of MSWs in HVLSPMSMs.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)