Abstract
This paper presents some considerations regarding the application of the stator zero-sequence current component (ZSC) in the fault detection of cage induction machines, including the effects of magnetic core saturation. Faults such as rotor cage asymmetry and static, dynamic, and mixed eccentricity were considered. The research started by developing a harmonic motor model, which allowed us to obtain a voltage equation for the zero-sequence current component. The equation allowed us to extract formulas of typical frequencies for particular fault types. Next, in order to verify the effectiveness of ZSC in induction motor fault diagnosis, finite element calculations and laboratory tests were carried out for the previously mentioned faults for delta and wye connections with neutral wire stator winding configurations.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)