The Effect of Dentine Desensitizing Agents on the Retention of Cemented Fixed Dental Prostheses: A Systematic Review

Author:

Sayed Mohammed E.1ORCID

Affiliation:

1. Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia

Abstract

Background and Objectives: The use of desensitizing agents (DA) after tooth preparation to prevent hypersensitivity is well documented in the literature. A fixed dental prosthesis (FDP) should have good retention to be successful. Inadequate retention may result in microleakage, secondary caries, and, eventually, dislodgement of the FDP. The effect of DAs on the retention of FDPs has been widely studied in the literature, but the results are conflicting. Thus, this study aimed to conduct a systematic review to assess the effect of dentine desensitizing agents, used to prevent post-cementation hypersensitivity, on the retention of cemented FDPs. The null hypothesis framed was that there is no effect of dentine desensitizing agents on the retention of cemented FDPs. The focused PICO question was as follows: “Does the application of dentine desensitizing agents (I) affect the retention (O) of cemented fixed dental prosthesis (P) when compared to non-dentine desensitizing groups (C)”? Materials and Methods: Four electronic databases were systematically searched and, on the basis of the predefined inclusion and exclusion criteria, 23 articles were included in this systematic review. A modified CONSORT scale for in vitro studies was used to assess the quality of the selected studies, as all included studies were in vitro studies. Results: Most of the studies compared the effect of more than one type of DA on retention. The results of the selected studies varied due to differences in the composition of tested dentine DAs and types of luting cements. Conclusions: Within the limitations of this study, it can be concluded that the retention values of FDPs cemented using zinc phosphate cement were reduced with most of the DAs, whereas retention values increased when GIC, resin-modified GIC, and resin cements were used with the majority of DAs. These findings are important, as they can guide dentists in selecting the DA before cementing the crowns with the luting agent of their choice, without compromising the retention of the crowns.

Publisher

MDPI AG

Subject

General Medicine

Reference65 articles.

1. Shillingburg, H.T., Hobo, S., and Whit, L.D. (1981). Fundamentals of Fixed Prosthodontics, Quintessence. [2nd ed.].

2. Hypersensitive teeth. Part I: Etiology;Krauser;J. Prosthet. Dent.,1986

3. Dentin permeability: Effects of crown preparation;Richardson;Int. J. Prosthodont.,1991

4. High and low torque handpieces: Cutting dynamics, enamel cracking and tooth temperature;Watson;Br. Dent. J.,2000

5. Effects of changes in surface area, thickness, temperature and postextraction tirne on human dentin permeability;Outhwaite;Arch. Oral Biol.,1976

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3