Nigro MariannaORCID,Valli GabrieleORCID,Marchionne Maria Luisa,Sattarinia Dario,Silvestrini Fabiana,De Pietro Daniele,Fazzini Simone,Roselli Giorgia,Spallino Andrea,Praticò Valentina,Mirante Enrico,Castaldo Ersilia,Pugliese Francesco Rocco,Cicchini Claudia,Ancona Carlo,De Marco Francesca,Ruggieri Maria Pia,Di Somma Salvatore

Abstract

Background and Objectives: Hemolysis is reported to be present in up to 10% of blood gas specimens in the central lab; however, few data on the incidence of hemolysis using a point-of-care testing (POCT) blood gas analysis are available in the setting of the emergency department. The aims of this study were: (1) to analyze the prevalence of hemolysis in blood gas samples collected in the ED using a POCT device; and (2) to evaluate the impact of hemolysis on blood sample results and its clinical consequences. Materials and Methods: We collected 525 consecutive POCT arterial blood gas samples using syringes with electrolyte-balanced heparin within 3 different EDs in the metropolitan area of Rome. Immediately after the collection, the blood samples were checked for the presence of hemolysis with a POCT instrument (i.e., HEMCHECK, H-10 ®). The samples were then subsequently processed for blood gasses, and an electrolytes analysis by a second operator blinded for the hemolysis results. A venous blood sample was simultaneously collected, analyzed for it’s potassium value, and used as a reference. Results: Of the samples, 472 were considered for the statistics, while 53 were excluded due to the high percentage of hemolysis due to operator fault in carrying out the measurement. The final mean hemolysis per operator was 12% (±13% SD), and the total final hemolysis was 14.4%.Potassium (K+) was significantly higher in the hemolyzed group compared with the non-hemolyzed sample (4.60 ± 0.11 vs. 3.99 ± 0.03 mEq/L; p < 0.001), and there were differences between arterial potassium versus venous potassium (D(a-v) K+, 0.29 ± 0.06 vs.−0.19 ± 0.02 mEq/L, p < 0.01). A Bland–Altman analysis confirmed that hemolysis significantly overestimated blood potassium level. Conclusion: Almost 12% of POCT blood gas analysis samples performed in the ED could be hemolyzed, and the presence of this hemolysis is not routinely detected. This could cause an error in the interpretation of the results, leading to the consideration of potassium concentrations being below the lower limit within the normal limits and also leading to the diagnosis of false hyperkalemia, which would have potential clinical consequences in therapeutic decision-making in the ED. The routine use of a POCT hemolysis detector could help prevent any misdiagnoses.

Publisher

MDPI AG

Subject

General Medicine

Reference27 articles.

1. Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories;Lippi;Clin. Chem. Lab. Med.,2008

2. Errors in laboratory medicine;Bonini;Clin. Chem.,2002

3. Blood sample quality;Lippi;Diagnnostics.,2019

4. The IFCC Working Group on laboratory errors and patient safety;Sciacovelli;Clin. Chim. Acta.,2009

5. (2022, December 13). Global Preanalytical Scientific Committee—SpecimenCare. Available online: https://specimencare.com/global-preanalytical-scientific-committee/.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3