Accuracy of ZedView, the Software for Three-Dimensional Measurement and Preoperative Planning: A Basic Study

Author:

Nozaki Asami1,Imai Norio2ORCID,Funayama Kazuhisa3,Horigome Yoji2,Suzuki Hayato1,Minato Izumi4,Kobayashi Koichi5,Kawashima Hiroyuki1

Affiliation:

1. Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510, Japan

2. Division of Comprehensive Musculoskeletal Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510, Japan

3. Division of Legal Medicine, Department of Community Preventive Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510, Japan

4. Department of Orthopedic Surgery, Niigata Rinko Hospital, Niigata 950-0051, Japan

5. School of Health Sciences, Faculty of Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510, Japan

Abstract

Background and Objectives: In the field of orthopedic surgery, novel techniques of three-dimensional shape modeling using two-dimensional tomographic images are used for bone-shape measurements, preoperative planning in joint-replacement surgery, and postoperative evaluation. ZedView® (three-dimensional measurement instrument and preoperative-planning software) had previously been developed. Our group is also using ZedView® for preoperative planning and postoperative evaluation for more accurate implant placement and osteotomy. This study aimed to evaluate the measurement error in this software in comparison to a three-dimensional measuring instrument (3DMI) using human bones. Materials and Methods: The study was conducted using three bones from cadavers: the pelvic bone, femur, and tibia. Three markers were attached to each bone. Study 1: The bones with markers were fixed on the 3DMI. For each bone, the coordinates of the center point of the markers were measured, and the distances and angles between these three points were calculated and defined as “true values.” Study 2: The posterior surface of the femur was placed face down on the 3DMI, and the distances from the table to the center of each marker were measured and defined as “true values.” In each study, the same bone was imaged using computed tomography, measured with this software, and the measurement error from the corresponding “true values” was calculated. Results: Study 1: The mean diameter of the same marker using the 3DMI was 23.951 ± 0.055 mm. Comparisons between measurements using the 3DMI and this software revealed that the mean error in length was <0.3 mm, and the error in angle was <0.25°. Study 2: In the bones adjusted to the retrocondylar plane with the 3DMI and this software, the average error in the distance from the planes to each marker was 0.43 (0.32–0.58) mm. Conclusion: This surgical planning software could measure the distance and angle between the centers of the markers with high accuracy; therefore, this is very useful for pre- and postoperative evaluation.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3