Abstract

Background and Objectives: The purpose of this study was to compare clinical outcomes and polyethylene (PE) insert thickness between total knee arthroplasty (TKA) systems providing 1 mm and 2 mm increments. Materials and Methods: In this randomized controlled trial, 50 patients (100 knees) undergoing same-day or staggered bilateral TKA were randomized to receive a TKA system providing 1 mm increments in one knee (1 mm group) and a TKA system providing 2 mm increments in the other knee (2 mm group). At 2 years postoperatively, Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, Forgotten Joint Score (FJS), range of motion (ROM), and insert thicknesses were compared between the groups. Results: A total of 47 patients (94 knees) participated in follow-up analysis. In each group, patient-reported outcomes improved significantly after TKA (all, p < 0.05). There were no significant differences in patient-reported outcomes. The mean ROM was not significantly different between groups at preoperative and 2-year points. The rate of postoperative flexion contracture ≥ 5° was 2.1% and 4.3%, and the rate of postoperative recurvatum ≥ 5° was 4.3% and 2.1% in the 1 mm group and 2 mm, respectively (all, p = 1.000). Mean insert thickness was significantly thinner in the 1 mm group than the 2 mm group (p = 0.001). The usage rate of a thick insert (≥14 mm) was 12.7% and 38.3% in the 1 mm group and 2 mm group (p = 0.005). Conclusions: The use of a TKA system providing 1 mm PE insert thickness increments offered no clinical benefit in terms of patient reported outcomes over systems with 2 mm increments at 2 years of follow-up. However, the TKA system with 1 mm increments showed significantly thinner PE insert usage. As a theoretical advantage of 1 mm increments has yet to be proven, the mid- to long-term effects of thinner PE insert usage must be determined.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3