Spectrophotometric Investigations of Charge Transfer Complexes of Tyrosine Kinase Inhibitors with Iodine as a σ-Electron Acceptor: Application to Development of Universal High-Throughput Microwell Assay for Their Determination in Pharmaceutical Formulations

Author:

Darwish Ibrahim A.1ORCID,Darwish Hany W.12,Ali Awadh M.1,Almutairi Halah S.1

Affiliation:

1. Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia

2. Department of Analytical Chemistry, Faculty of Pharmacy, Cairo University, Kasr El-Aini St., Cairo 11562, Egypt

Abstract

Background and Objective: Tyrosine kinase inhibitors (TKIs) are used for the treatment of different types of cancers. The current study describes, for the first time, the ultraviolet-visible spectrophotometric investigation of charge transfer complexes (CTCs) of seven TKIs, as electron donors, and iodine, as σ-electron. Materials and Methods: The formation of CTCs was promoted in dichloromethane, among the other solvents used in the investigation. The molar absorptivity values, association constants, and free energy changes of the CTCs were determined. Stoichiometric ratio of TKI: iodine as well as TKIs site(s) of interaction were addressed. Reaction was the basis for constructing a novel simple and accurate 96-microwell spectrophotometric assay (MW-SPA) with high-throughput property for the quantitative determination of TKIs in their pharmaceutical formulations. Results: Beer’s law, which relates CTC absorbances to TKI concentrations, was followed within the optimal range of 2 to 100 µg/well (r ranged from 0.9991 to 0.9998). Detection and quantification limits ranged from 0.91 to 3.60 and 2.76 to 10.92 g µmL−1, respectively. Relative standard deviations values for the intra- and inter-assay precisions of the proposed MW-SPA did not exceed 2.13 and 2.34%, respectively. Studies of recovery demonstrated MW-SPA accuracy, with results ranging from 98.9% to 102.4%. All TKIs, both in bulk form and in pharmaceutical formulations (tablets), were effectively determined using the suggested MW-SPA. Conclusions: The current MW-SPA involved a simple procedure and it was convenient as it could analyse all proposed TKIs utilizing a single assay system at once measuring wavelengths for all TKIs. In addition, the proposed MW-SPA has high throughput which enables the processing of a batch of huge samples’ number in very short reasonable time period. In conclusion, TKIs can be routinely analysed in their dosage forms in quality control laboratories, and the assay can be highly valuable and helpful in this regard.

Funder

Ministry of Education in Saudi Arabia

Publisher

MDPI AG

Subject

General Medicine

Reference60 articles.

1. (2023, April 02). World Health Organization, Geneva, Report 3 February 2022. Available online: https://www.who.int/news-room/fact-sheets/detail/cancer.

2. Knowledge of secondary-school female students on breast cancer and breast self-examination in Jeddah, Saudi Arabia;Milaat;East. Mediterr. Health J.,2000

3. Locally advanced breast cancer in Saudi Arabia: High frequency of stage III in a young population;Ezzat;Med. Oncol.,1999

4. Adolescents and cancer: A survey of knowledge and attitudes about cancer in eastern province of Saudi Arabia;Hashim;J. Fam. Community Med.,2000

5. Global cancer control: Responding to the growing burden, rising costs and inequalities in access;Prager;ESMO Open,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3