Atrial Pacing Affects Left Atrial Morphological and Functional Parameters Early after Pacemaker Implantation

Author:

Viezelis Mindaugas,Neverauskaite-Piliponiene Gintare,Marcinkeviciene Agne,Teleisyte Eligija,Kazakevicius Tomas,Zabiela Vytautas,Kviesulaitis Vilius,Jurkevicius Renaldas,Puodziukynas Aras

Abstract

Background and Objectives: Chronic atrial stimulation might impair left atrial (LA) function. We aimed to assess the impact of atrial pacing burden on LA volumetric and functional parameters after implantation of a dual-chamber pacemaker. Materials and Methods: The prospective study included 121 subjects with sinus node disease (SND) or atrioventricular block (AVB) that received a dual-chamber pacemaker. After device implantation, the subjects were divided into three groups: (1) SND with a lower rate (LR) set to 60 bpm and rate response enabled; (2) AVB with an LR set to 60 bpm and no rate response; and (3) AVB with an LR set to 40 bpm and no rate response. Subjects were followed at one and three months. Two subsets of patients with high and low atrial pacing burdens accompanied by low ventricular pacing percentage were analyzed. LA function was evaluated with volumetric and strain parameters from transthoracic echocardiography. Results: The high atrial low ventricular pacing group consisted of 38 subjects, and the low atrial low ventricular group consisted of 22 subjects. When looking at the change in volumetric parameters, we observed a tendency for volumes to increase in both groups; however, only minimal LA volume reached statistical significance at three months in the high atrial pacing group. A trend towards the lowering of an active emptying fraction at one month (p = 0.076) became significant at three months (p = 0.043), and was also only observed in the same group. Moreover, a decrease in the tendency to reach statistical significance at three months for reservoir and contractile strain parameters and stiffness index was only observed in the high atrial pacing group. Meanwhile, in the low atrial pacing burden group, all parameters remained significantly unchanged. Conclusions: The burden of right atrial pacing in patients with preserved left ventricular function negatively influences functional and morphologic LA parameters. Moreover, negative effects take place soon after pacemaker implantation and appear to be sustained.

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3