Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings

Author:

ALMisned Ghada1,Elshami Wiam2ORCID,Kilic Gokhan3ORCID,Ilik Erkan3ORCID,Rabaa Elaf2,Zakaly Hesham M. H.45ORCID,Ene Antoaneta6ORCID,Tekin Huseyin O.27

Affiliation:

1. Department of Physics, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia

2. Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates

3. Department of Physics, Faculty of Science, Eskisehir Osmangazi University, Eskisehir 26040, Türkiye

4. Institute of Physics and Technology, Ural Federal University, 620002 Ekaterinburg, Russia

5. Physics Department, Faculty of Science, Al-Azhar University, Assiut 71524, Egypt

6. INPOLDE Research Center, Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, Dunarea de Jos University of Galati, 47 Domneasca Street, 800008 Galati, Romania

7. Computer Engineering Department, Faculty of Engineering and Natural Sciences, Istinye University, Istanbul 34396, Türkiye

Abstract

Background: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. Materials and Methods: A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.7.0) Monte Carlo code. An MCNPX-simulation geometry was designed and implemented, using the lead-acrylic and TZI8 shielding screens between the right and left breast. Next, the reliability of the phantom and the variations in absorption between the lead-acrylic and TZI8 glass were investigated. Results: The findings show that the TZI8-protective-glass screen offers significantly greater radioprotection than the lead-acrylic material. The quantity of total dose absorbed in the unexposed breast was much lower for TZI8 than for lead-based acrylic. The TZI8-glass screen gives about 60% more radioprotection than the lead-acrylic screen. Conclusion: Considering the toxic lead in the structure that may be hazardous to the human tissues, the TZI8-glass screen may be used in mammography examination to provide greater radioprotection than the lead-acrylic screen, in order to greatly reduce the dose to the unexposed breast.

Funder

Princess Nourah bint Abdulrahman University

Publisher

MDPI AG

Subject

General Medicine