Accuracy of Computer-Guided Implantology with Pilot Drill Surgical Guide: Retrospective 3D Radiologic Investigation in Partially Edentulous Patients

Author:

Gelpi Federico1ORCID,Modena Nicolò2,Poscolere Alessandro2,Bernardello Fabio2ORCID,Torroni Lorena3ORCID,De Santis Daniele1

Affiliation:

1. Head and Neck Department, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, 37124 Verona, Italy

2. Private Practitioner, 37124 Verona, Italy

3. Unit of Epidemiology and Medical Statistics, Department of Diagnostics & Public Health, University of Verona, 37129 Verona, Italy

Abstract

Background and Objectives: Implant placement with static navigation enables the reaching of a correct position of implants from an anatomical and prosthetic point of view. Different approaches of static navigation are described in the scientific literature, and the pilot-guided approach is one of the least investigated. The aim of the present study is the evaluation of the accuracy of implant insertion using a pilot drill template. Materials and Methods: Fifteen partially edentulous patients, requiring an implant rehabilitation of at least one implant, were enrolled. Pre- and post-operative low-dose CTs were acquired to measure the differences between final positions of implants and virtually planned ones. Three linear discrepancies (coronal, apical, and depth), two angular ones (bucco-lingual and mesio-distal), and the imprecision area were evaluated. Correlations between accuracy and rehabilitated jaws, sectors, and implant length and diameters were also analyzed. Results: Forty implants were inserted in fifteen patients using pilot drill templates. Mean coronal deviation was 1.08 mm, mean apical deviation was 1.77 mm, mean depth deviation was −0.48 mm, mean bucco-lingual angular deviation was 4.75°, and mean mesio-distal one was 5.22°. The accuracy was statistically influenced only by the rehabilitated jaw for coronal discrepancy and sectors and implant diameter for bucco-lingual angular deviations. Conclusions: The pilot drill template could represent a predictable solution to obtain a correct implant placement. Nonetheless, a safety margin of at least 2 mm should be respected during implant planning to prevent damages to anatomical structures. Therefore, the tool is helpful in order to prosthetically drive the implants; still, great attention must be paid in fully relying on this procedure when approaching dangerous structures such as nerves and vessels.

Publisher

MDPI AG

Subject

General Medicine

Reference35 articles.

1. A multicenter report on osseointegrated oral implants;Albrektsson;J. Prosthet. Dent.,1988

2. Survival of the Brǻnemark implant in partially edentulous jaws: A 10-year prospective multicenter study;Lekholm;Int. J. Oral Maxillofac. Implant.,1999

3. Implant treatment in the edentulous mandible: A prospective study on Brǻnemark system implants over more than 20 years;Ekelund;Int. J. Prosthodont.,2003

4. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years;Pjetursson;Clin. Oral Implant. Res.,2004

5. Implant treatment in the edentulous maxillae: A 15-year follow-up study on 76 consecutive patients provided with fixed prostheses;Jemt;Clin. Implant. Dent. Relat. Res.,2006