The Value of Ultrasound in the Evaluation of the Integrity of Silicone Breast Implants

Author:

Rukanskienė DaliaORCID,Bytautaitė Greta,Česnauskaitė Agnė,Pilipaitytė Loreta,Aštrauskas Tautrimas,Jonaitienė Eglė

Abstract

Background and Objective: Breast implant surgery for cosmetic purposes is the most popular plastic surgery and it has been performed for over 100 years. Rupture of silicone gel-filled breast implants usually is asymptomatic and is one of the more dangerous complications due to free silicone migration. The aim of our study was to evaluate the diagnostic value of ultrasound (US) in the evaluation of the integrity of silicone breast implants and identify the main sign of intact and ruptured breast implants. Patients and Methods: In this retrospective study, the medical documentation of women who underwent breast implant surgery and US checkups at Tautrimas Aštrauskas Clinic in Kaunas, Lithuania, during 2015–2020 was analyzed. The patients were divided into two groups: patients with intact and ruptured breast implants. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as the signs of implant integrity of US examination were evaluated. Results: In this study, 76 women with bilateral breast implants (n = 152) were reviewed. On a US examination, ruptured implants were found in 41.1% (n = 61) of the cases; of them, 78.7% (n = 48) of the cases had ≥2 US signs of a ruptured implant, and in all these cases, implant rupture was confirmed at surgery. Overall, one US sign of a ruptured implant was found in 21.3% (n = 13) of the cases. Of them, inhomogeneous content in all cases (n = 3) was found in the intact implant group, and an abnormal implant shell was documented more often in the ruptured implant group, not intact one (n = 9, 90% vs. n = 1, 10%). US had a diagnostic accuracy of 94.7%, sensitivity of 98.3%, specificity of 89.2%, PPV of 93.4%, and NPV of 97.1% in the evaluation of implant integrity. Conclusions: Our results show that US is a very reliable alternative in evaluating breast implant integrity and could be the investigation of choice for implant rupture, while MRI could be advocated only in inconclusive cases. Uneven implant shell was found to be the most important US sign of breast implant rupture. Based on the findings, we recommend performing US examination after breast augmentation surgery with silicone gel-filled implants annually.

Publisher

MDPI AG

Subject

General Medicine

Reference29 articles.

1. Plastic Surgery Statistics|American Society of Plastic SurgeonsHttps://www.plasticsurgery.org/news/plastic-surgery-statistics

2. BREASTCANCER.ORGHttps://www.breastcancer.org/treatment/surgery/reconstruction/corrective/implant-rupture

3. Accuracy of mammography, sonography and magnetic resonance imaging for detecting silicone breast implant ruptures: A retrospective observational study of 367 cases

4. Silicone breast implant rupture: a review

5. Giant siliconoma mimicking locally advanced breast cancer: A case report and review of literature

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献