A New Model of Salivary Pacemaker—A Proof of Concept and First Clinical Use

Author:

Funieru Cristian1,Tudose Dan Ștefan2,Dobrică Bogdan3,Săndulescu Mihai4ORCID,Popovici Ion Alexandru4,Slușanschi Emil Ioan2,Croitoru Sorin Mihai5,Vrînceanu Daniela6,Bănică Bogdan7,Nicolescu Mihnea Ioan89ORCID

Affiliation:

1. Preventive Dentistry Department, Faculty of Dentistry, Carol Davila University of Medicine and Pharmacy, 4 Eforiei, 050037 Bucharest, Romania

2. Computer Science and Engineering Department, Faculty of Automatic Control and Computer Science, Politehnica University of Bucharest, 313 Splaiul Independenţei, 060042 Bucharest, Romania

3. NanoSAE Research Centre, Faculty of Physics, University of Bucharest, 405 Atomiştilor, 077125 Bucharest-Măgurele, Romania

4. Department of Implant Prosthetic Therapy, Faculty of Dentistry, Carol Davila University of Medicine and Pharmacy, 17-23 Plevnei, 010221 Bucharest, Romania

5. Department of Machine Tools and Manufacturing Systems, Faculty of Industrial Engineering and Robotics, Politehnica University of Bucharest, 313 Splaiul Independenţei, 060042 Bucharest, Romania

6. ENT Department, Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 169 Splaiul Independenței, 050098 Bucharest, Romania

7. Oral and Maxillofacial Surgery Department, University Emergency Hospital Bucharest, 169 Splaiul Independenţei, 050098 Bucharest, Romania

8. Histology Division, Faculty of Dentistry, Carol Davila University of Medicine and Pharmacy, 8 Eroii Sanitari, 050474 Bucharest, Romania

9. Radiobiology Laboratory, Victor Babeș National Institute of Pathology, 99-101 Splaiul Independenţei, 050096 Bucharest, Romania

Abstract

Background and Objectives: Saliva is of utmost importance for maintaining oral health. Management of saliva flow rate deficiency recently includes salivary neuro-electrostimulation. The aim of this paper is to present a new model of salivary pacemaker—the MICROSAL device (MD), an intelligent, miniaturized, and implant-supported oral device used for salivary stimulation. Materials and Methods: This report presents the development, calibration, and first clinical tests which involved the MD. The novel features of this device are the pH sensor and the fact that it communicates with the patient’s smartphone, where oral wetness and pH are graphically exposed. Saliva samples were taken before and after the MD was used on a 68-year-old patient suffering from post-irradiation xerostomia, and albumin and total protein were analyzed. Results: The device uses up to 3 V and time intervals of 2 s seconds for stimulation. The total volume of all saliva samples collected during the clinical trial was almost seven times higher after the device was used. Albumin decreased from a maximum of 0.15 g/dL to 0.04 g/dL, and total proteins from 0.65 g/dL to 0.21 g/dL, after salivary stimulation. Conclusions: The MD increased saliva secretion of the patient, and we are confident it will be a good solution for future management of salivary gland hypofunction.

Funder

UEFISCDI—Romanian Ministry of Education

University of Medicine and Pharmacy Carol Davila

Publisher

MDPI AG

Subject

General Medicine

Reference31 articles.

1. Hyposalivation in elderly patients;Gupta;J. Can. Dent. Assoc. Tor.,2006

2. Xerostomia: An update for clinicians;Hopcraft;Aust. Dent. J.,2010

3. Health benefits of saliva: A review;Dodds;J. Dent.,2005

4. World Workshop on Oral Medicine VI: A systematic review of medication-induced salivary gland dysfunction: Prevalence, diagnosis, and treatment;Villa;Clin. Oral Investig.,2015

5. Xerostomia due to systemic disease: A review of 20 conditions and mechanisms;Baharvand;Ann. Med. Health Sci. Res.,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3