Duplex Analysis of Cannulated Vessels in Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation

Author:

Simons JorikORCID,Agricola Sandra,Smets Jeroen,Metz Renske,Mariani SilviaORCID,Vleugels Marie-José,Smeets Reinier R.,van Mook Walther N. K. A.ORCID,Mees BarendORCID,Lorusso RobertoORCID

Abstract

Background and objectives: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) cannulas have major repercussions on vascular hemodynamics that can potentially lead to limb ischemia. Duplex ultrasound enables the non-invasive analysis of vascular hemodynamics. This study aims to describe the duplex parameters of the femoral vessels during V-A ECMO support, investigate differences between cannulated and non-cannulated vessels, and analyze the variations in the case of limb ischemia and intra-aortic balloon pumps (IABPs). Methods: Nineteen adults (≥18 years), supported with femoro-femoral V-A ECMO, underwent a duplex analysis of the superficial femoral arteries (SFAs) and veins (FVs). Measured parameters included flow velocities, waveforms, and vessel diameters. Results: 89% of patients had a distal perfusion cannula during duplex analysis and 21% of patients developed limb ischemia. The mean peak systolic flow velocity (PSV) and end-diastolic flow velocity (EDV) of the SFAs on the cannulated side were, respectively, 42.4 and 21.4 cm/s. The SFAs on the non-cannulated side showed a mean PSV and EDV of 87.4 and 19.6 cm/s. All SFAs on the cannulated side had monophasic waveforms, whereas 63% of the SFAs on the non-cannulated side had a multiphasic waveform. Continuous/decreased waveforms were seen in 79% of the FVs on the cannulated side and 61% of the waveforms of the contralateral veins were respirophasic. The mean diameter of the FVs on the cannulated side, in patients who developed limb ischemia, was larger compared to the FVs on the non-cannulated side with a ratio of 1.41 ± 0.12. The group without limb ischemia had a smaller ratio of 1.03 ± 0.25. Conclusions: Femoral cannulas influence flow velocities in the cannulated vessels during V-A ECMO and major waveforms alternations can be seen in all SFAs on the cannulated side and most FVs on the cannulated side. Our data suggest possible venous stasis in the FV on the cannulated side, especially in patients suffering from limb ischemia.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3