Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography

Author:

Dong Jing1,Yao Jinhan2,Chang Shuimiao2,Kanclerz Piotr34ORCID,Khoramnia Ramin5ORCID,Wang Xiaogang2ORCID

Affiliation:

1. Department of Ophthalmology, First Hospital of Shanxi Medical University, Taiyuan 030001, China

2. Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan 030002, China

3. Hygeia Clinic, 80-286 Gdańsk, Poland

4. Helsinki Retina Research Group, University of Helsinki, 00014 Helsinki, Finland

5. The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany

Abstract

Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0°–180°, 30°–210°, 60°–240°, 90°–270°, 120°–300°, and 150°–330°) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson’s correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 ± 0.08 mm (p = 0.005) and 0.21 ± 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 ± 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW.

Funder

Shanxi Scholarship Council of China

Publisher

MDPI AG

Subject

General Medicine

Reference33 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3