Affiliation:
1. Division of Vascular Surgery, 1st Surgical Department, Faculty of Health Sciences, Papageorgiou General Hospital, Aristotle University, 56403 Thessaloniki, Greece
2. Department of Radiology, Papageorgiou General Hospital, 56403 Thessaloniki, Greece
Abstract
Background: Prospective single and multicenter studies have shown improved outcomes of patients who underwent carotid artery stenting with the novel CGuard dual-layer mesh stent at 1 year. Objectives: The aim of this study is to conduct a systematic review and meta-analysis of all published studies to assess 1-year efficacy and outcomes of CGuard in patients with carotid stenting. Methods: A systematic search was performed. All studies enrolling at least 20 patients were included in our analysis. The primary endpoints were death (all-cause, cardiovascular and ipsilateral stroke-related death) and stroke rate at 1 year. The secondary endpoint was in-stent restenosis at 1 year. Results: The final analysis included 1709 patients. The one-year all-cause mortality rate was 2.97% (39/1699, 95% CI: 1.26–6.86%, I2 = 67%, t2 = 0.3442, p < 0.01), cardiovascular-related death was 0.92% (10/1616, 95% CI: 0.35–2.39%, I2 = 34%, t2 = 0.2302, p = 0.18), and ipsilateral stroke-related death was 0.3% (1/1649, 95% CI: 0.1–0.87%, I2 = 0%, t2 = 0, p = 0.69). The one-year ipsilateral stroke rate was 1.21% (16/1649, 95% CI: 0.58–2.5%, I2 = 28%, t2 = 0.1433, p = 0.23), transient ischemic attacks (TIAs) rate was 1.78% (19/1149, 95% CI: 1.11–2.84%, I2 = 0%, t2 = 0, p = 0.69), and total composite 1-year stroke/TIA rate was 2.97% (32/1149, 95% CI: 1.84–4.77%, I2 = 0%, t2 = 0, p = 0.41). The in-stent restenosis rate at 1 year was 1.06% (13/1653, 95% CI: 0.48–2.34%, I2 = 28%, t2 = 0.2308, p = 0.22). Conclusions: This meta-analysis shows that CAS with CGuard is safe with minimal neurological adverse events and in-stent restenosis rate at 1 year.
Reference32 articles.
1. Stroke after carotid stenting and endarterectomy in the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST);Hill;Circulation,2012
2. New ischemic brain lesions on MRI after stenting or endarterectomy for symptomatic carotid stenosis: A sub study of the International Carotid Stenting Study (ICSS);Bonati;Lancet Neurol.,2010
3. The CAPTURE registry-Analysis of strokes resulting from carotid artery stenting in the post approval setting: Timing, location, severity, and type;Fairman;Ann. Surg.,2007
4. Does free cell area influence the outcome in carotid artery stenting?;Bosiers;Eur. J. Vasc. Endovasc. Surg.,2007
5. Christopher, M.D. (2023, January 1). 30-Day Results from the C-Guardians Pivotal Trial of the CGuard™ Carotid Stent System. Proceedings of the VIVA 2023, Las Vegas, NV, USA.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献