Electromyographic Evaluation of Muscle Activity in Patients Rehabilitated with Full Arch Fixed Implant-Supported Prostheses

Author:

Mostovei Mihail1ORCID,Solomon Oleg1,Chele Nicolae2,Sinescu Cosmin3ORCID,Duma Virgil-Florin45ORCID,Mostovei Andrei2

Affiliation:

1. Department of Prosthetic Dentistry, State University of Medicine and Pharmacy “Nicolae Testemițanu”, 165 Ştefan cel Mare şi Sfânt Ave., MD-2004 Chisinau, Moldova

2. Department of Oro-Maxillo-Facial Surgery and Oral Implantology, State University of Medicine and Pharmacy “Nicolae Testemițanu”, 165 Ştefan cel Mare şi Sfânt Ave., MD-2004 Chisinau, Moldova

3. Research Center in Dental Medicine Using Conventional and Alternative Technologies, School of Dental Medicine, “Victor Babes” University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave., 300070 Timisoara, Romania

4. 3OM Optomechatronics Group, Faculty of Engineering, Aurel Vlaicu University of Arad, 2 Elena Dragoi Str., 310177 Arad, Romania

5. Doctoral School, Polytechnic University of Timisoara, 1 Mihai Viteazu Ave., 300222 Timisoara, Romania

Abstract

Background and Objectives: Implant rehabilitation of complete edentulous arches has become more and more popular because of the increased access of the population to this type of treatment. Furthermore, the development of new rehabilitation procedures can be applied in most clinical cases, including in those with severe atrophy. Hence, this study aimed to assess the functional changes that can occur in the stomatognathic system after implant rehabilitation procedures. Materials and Methods: A total of 63 patients were accepted in the study. They were divided into a first control (dentate) group (CG) and a second study group (edentulous, SG). For the latter, 30 patients received 204 two-stage implants immediately loaded with provisional prostheses. Surface electromyography (EMG) was assessed at the time of prostheses fixation, while for some patients it was applied six months after the fixation of the fixed prostheses, as well. These supplemental investigated patients formed a third, follow-up study group (FSG). All assessments were performed during the processes of clenching and mastication. The obtained data of the two study groups, SG and FSG, were compared with those of the control group, CG. Results: No statistical differences were found in the electrical muscular activity between the study and control groups during both clenching and mastication (p > 0.05). In addition, there were no differences within the same study group, both initially and after 6 months. The only changes were noticed between static and dynamic values for the right masseter muscle in the follow-up group FSG (p = 0.008). Deviations of the overlapping coefficients were similar for all groups (p = 0.086): for CG, 20.5%, median 11.1 (min. 0, max. 104); for SG, 21.4%, median 12.2 (min. 0, max. 103); for FSG, 36.1%, median 26.9 (min. 0, max. 160). This revealed no neuromuscular adaption to the prostheses. Conclusions: Implant-prosthetic rehabilitation led to an EMG activity that was similar to that of dentate patients immediately after the placement of the fixed implant-supported prostheses. Moreover, the measured values did not change after six months of functioning for all evaluated parameters. This may point to an immediate restoration of the muscle contraction capacity, without the necessity of adaptation over time. The study serves as an argument for the application and reliability of the immediate fixed implant-supported prostheses from the perspective of muscle adaptation and functioning.

Funder

Romanian Ministry of Research, Innovation and Digitization

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3