High Percentage of Complications and Re-Operations Following Dynamic Locking Plate Fixation with the Targon® FN for Intracapsular Proximal Femoral Fractures: An Analysis of Risk Factors

Author:

Kuner Emanuel,Gütler Jens,Delagrammaticas Dimitri E.,van de Wall Bryan J. M.,Knobe MatthiasORCID,Beeres Frank J. P.,Babst Reto,Link Björn-ChristianORCID

Abstract

The ideal surgical treatment of femoral neck fractures remains controversial. When treating these fractures with internal fixation, many fixation constructs exist. The primary aim of this study was to evaluate the incidence and specific risk factors associated with complication and re-operation following fixation of intracapsular proximal femoral fractures using the Targon-FN system (B.Braun Melsungen AG). A secondary aim was to identify if lateral prominence of the implant relative to the lateral border of the vastus ridge was a specific risk factor for elective plate removal. Methodically, a retrospective case series was conducted of all consecutive adult patients treated at a single level 1 trauma center in Switzerland for an intracapsular proximal femoral fracture with the Targon-FN. Demographic data were collected. Patients with a follow-up of less than three months were excluded. Complications as well as plate position were recorded. Statistical analysis to identify specific risk factors for re-operation and complications was performed. In result, a total of 72 cases with intracapsular femoral neck fractures were treated with the Targon-FN locking plate system between 2010 and 2017. Thirty-four patients (47.2%) experienced one or more complications. The most common complication was mechanical irritation of the iliotibial band (ITB) (23.6%, n = 17). Complications included intraarticular screw perforation (6.9%, n = 5), avascular necrosis (5.6%, n = 4), non-union (5.6%, n = 4) among others. In total, 46 re-operations were required. Younger age, fracture displacement and time to postoperative weight bearing were identified as risk factors for re-operation. In conclusion, intracapsular femoral neck fractures treated with the Targon-FN system resulted in a high rate of post-operative complication and re-operation. Statistical analysis revealed patient age, fracture displacement, time to postoperative full weight bearing were risk factors for re-operation. The main limitation is the limited number of cases and a short follow-up of less than 12 months in a subgroup of our patients.

Publisher

MDPI AG

Subject

General Medicine

Reference44 articles.

1. Cemented or uncemented hemiarthroplasty for displaced intracapsular fractures of the hip: A randomized trial of 400 patients;Parker;Bone Jt. J.,2019

2. Der Oberschenkelhalsbruch;Lucke;Dtsch. Arztebl.,2005

3. Hüftgelenknahe Frakturen im hohen Lebensalter;Knobe;Orthopäde,2014

4. Comparison of Internal Fixation with Total Hip Replacement for Displaced Femoral Neck Fractures: Randomized, Controlled Trial Performed at Four Years;Blomfeldt;JBJS,2005

5. Factors predicting healing complications in femoral neck fractures: 138 patients followed for 2 years;Nilsson;Acta Orthop. Scand.,1993

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Current Management of Hip Fracture;Medicina;2022-12-23