Do Stainless-Steel Pins Coated with Fibroblast Growth Factor–Calcium Phosphatase Composite Layers Have Anti-Infective Effects?

Author:

Totoki Yasukazu1ORCID,Mutsuzaki Hirotaka23,Yanagisawa Yohei1ORCID,Sogo Yu4,Yasunaga Mayu4,Noguchi Hiroshi1ORCID,Matsumoto Yukei1,Koda Masao1,Ito Atsuo4ORCID,Yamazaki Masashi15

Affiliation:

1. Department of Orthopaedic Surgery, University of Tsukuba, Tsukuba 305-8571, Ibaraki, Japan

2. Center for Medical Science, Ibaraki Prefectural University of Health Sciences, Ami 300-0394, Ibaraki, Japan

3. Department of Orthopedic Surgery, Ibaraki Prefectural University of Health Sciences Hospital, Ami 300-0331, Ibaraki, Japan

4. National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute, Tsukuba 305-8566, Ibaraki, Japan

5. Department of Orthopaedic Surgery, Ichihara Hospital, Tsukuba 300-3295, Ibaraki, Japan

Abstract

Background: The most problematic complication of external fixation is infection at the pin insertion site. Technology that improves the adhesion of the external fixation pin to the skin, subcutaneous tissue, and bone may prevent infection at the pin site. The purpose of this study is to formulate a calcium phosphate–fibroblast growth factor (Cp-FGF) coating on a stainless-steel external fixation pin and to verify its effectiveness in reducing infection at the pin site and its possible influence on bone fixation in animal experiments. Methods: We compared stainless-steel screws without coating (SS group; n = 32), those with a calcium phosphate coating (Cp group; n = 30), those with a Cp-FGF coating (FGF group; n = 32), and those with a Cp-FGF coating having enhanced biological activity (FGF+ group; n = 32) in male Japanese white domesticated rabbits. Screws were inserted percutaneously into the bilateral proximal tibial diaphysis of the rabbits and implanted for 4 weeks. Screws and periscrew tissue were observed postoperatively for qualitatively assessing infection. Results: Infection assessment by gross findings after 4 weeks (at screw removal) showed no significant differences between the groups. Histopathological evaluation of soft tissue infection and bone tissue infection showed no significant differences between the groups for either soft tissue or bone tissue. Since neither the FGF+ group nor the FGF group showed anti-infective effects, the biological activity of FGF is not the only determining factor. We compared SEM, XRD, coating detaching test, sustained release test, and bioassay to examine physicochemical properties among the coatings but found no sufficient differences. Conclusions: It is suggested that improving the tissue adhesion to and/or biocompatibility of pins is also important to improve the in vivo performance of Cp-FGF-coated external fixation pins.

Funder

JSPS KAKENHI

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3