In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations

Author:

Cîmpean Sanda Ileana1,Chisnoiu Radu Marcel1,Colceriu Burtea Adela Loredana1,Rotaru Rareș2,Bud Marius Gheorghe1,Delean Ada Gabriela1,Pop-Ciutrilă Ioana-Sofia1

Affiliation:

1. Department of Odontology, Endodontics and Oral Pathology, “Iuliu Hațieganu” University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania

2. Student at Faculty of Dental Medicine, “Iuliu Hațieganu” University of Medicine and Pharmacy, 400001 Cluj-Napoca, Romania

Abstract

Background and Objectives: The aim of this study was to compare the accuracy of three types of electronic apex locators (EALs) when two different concentrations of NaOCl irrigation solutions are used by two operators. Materials and Methods: After creating the access cavities for 20 single rooted extracted teeth, the actual canal length (ACL) of each canal was determined visually using a #10 file and magnification. The teeth were subsequently inserted in plastic molds filled with alginate. The electronic measurement of root canal length (EWL) was performed using three different electronic apex locators: Root ZX II, Apex ID, and Dual Pex. Two independent operators, an endodontic specialist with 20 years practice and an undergraduate student in the final year of study, performed the irrigation procedures with two different concentrations of NaOCl (2% and 5.25%), and then measured the EWL using each of the EALs. The accuracy of all EALs, was determined in each case by subtracting the EWL from the ACL. Statistical analyses were performed using one-way ANOVA test. Results: In the presence of 2% NaOCl solution, for a margin error of ±0.5 mm, Root ZX II, Apex ID, and Dual Pex presented an accuracy of 90%, 80%, and 85% respectively. The increase in the concentration of the irrigation solution affected the accuracy of Root ZX II and Apex ID for both operators, diminishing it to 75% for the same margin error, but improved Dual Pex’s accuracy to 100%. Conclusions: The best accuracy in working length determination was obtained by Root ZX II for 2% NaOCl solution and by Dual Pex for 5.25% NaOCl solution with no significant statistical difference when compared.

Publisher

MDPI AG

Subject

General Medicine

Reference44 articles.

1. An ex vivo comparison of working length determination by 3 electronic apex locators;Pascon;Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol.,2009

2. Schilder, H. (1976). Cohen S & Burns RC, Eds Pathways of the Pulp, C.V. Mosby. [2nd ed.].

3. Apical Constriction: Location and Dimensions in Molars—A Micro–Computed Tomography Study;ElAyouti;J. Endod.,2014

4. Apical terminus location of root canal treatment procedures;Wu;Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol.,2000

5. The position and topography of the apical canal constriction and apical foramen;Dummer;Int. Endod. J.,1984