Risk Factors and Clinical Outcomes of Osteotomy Plane Violation by D-Hole Screws in Medial Open Wedge High Tibial Osteotomy: A Simulation and Comparative Study

Author:

Kim Sung Eun12ORCID,Lee Myung Ho1ORCID,Cho Chan Hee1ORCID,Lee Jung-In1ORCID,Han Hyuk-Soo12ORCID,Lee Myung Chul12,Ro Du Hyun123ORCID

Affiliation:

1. Department of Orthopaedic Surgery, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, 110-744, Seoul 03080, Republic of Korea

2. Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul 03080, Republic of Korea

3. CONNECTEVE Co., Ltd., Seoul 06249, Republic of Korea

Abstract

Background and Objectives: Stable fixation is essential for successful healing after medial open wedge high tibial osteotomy (MOWHTO) to minimize the risk of non-union and correction loss. In Asians, potential complications such as D-hole screw osteotomy plane violation (D-hole violation) and inadequate plate fitting arise due to improper plate size. This study aimed to evaluate the risk factors for D-hole violation and compare the conventional anatomic (CA) plate with an individualized anatomic (IA) plate in MOWHTO procedures. Materials and Methods: A simulation study on D-hole violation using the CA plate was conducted, involving preoperative radiographs and CT scans of 64 lower extremities from 47 MOWHTO patients. Additionally, a randomized controlled study compared CA and IA plates in MOWHTO procedures with 34 patients (17 in the CA plate group; 18 in the IA plate group). Patient demographics, patient-reported outcome measures (PROMs), and radiological measures were analyzed. Results: In the simulation study, the rates of D-hole violation ranged from 20.3% to 59.4%, with an increase observed as the plate was distalized from 5 mm to 10 mm away from the joint line. Short stature was identified as an independent risk factor for D-hole violation (p < 0.001), with a cutoff value of 155.3 cm. In the randomized controlled study, no significant difference in PROMs and D-hole violation was observed between the CA plate and IA plate groups. However, the IA plate group showed better plate fitting compared to the CA plate group (p = 0.041). Conclusions: This study identified a high risk of D-hole screw osteotomy plane violations in MOWHTO procedures, particularly when the plate is positioned more distally and in individuals with a stature below 155.3 cm. It also revealed that individualized plates provide better tibial fitting compared to conventional anatomic plates, particularly in Asian populations where tibial morphology tends to be shorter than in Western populations. Therefore, evaluating patient stature and selecting tailored plates are essential to optimize plate positioning and minimize plate-related complications in MOWHTO procedures.

Funder

Korea Medical Device Development Fund

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3