Muscle Quality of Knee Extensors Based on Several Types of Force in Multiple Sclerosis Patients with Varying Degrees of Disability

Author:

Portilla-Cueto Kora,Medina-Pérez CarlosORCID,Romero-Pérez Ena MonserratORCID,Núñez-Othón Gabriel,Horta-Gim Mario A.,de Paz José AntonioORCID

Abstract

Background and Objectives: Multiple sclerosis (MS) tends to affect muscle performance, mainly in the lower extremities. The degree of disability is associated with the loss of strength and muscle mass, to varying extents. Muscle quality (MQ) expresses the amount of force produced relative to the activated muscle mass. The purpose of this study was to compare the MQ of the knee extensors in the main manifestations of strength (isometric, dynamic strength, and power) among patients with differing degrees of neurological disability and evolutionary forms of the disease. We also establish reference values for MQ in MS patients (pwMS). Materials and Methods: In total, 250 pwMS were evaluated according to the Expanded Disability Status Scale (EDSS). The maximum dynamic and isometric forces and muscle power manifested a load of 60% of the maximum dynamics of the knee extensors. The lean mass of the thigh and hip was determined by densitometry, and the MQ was calculated for the three types of force evaluated. Results: The pwMS with relapsing remitting MS (RRMS) presented isometric MQ values that were 15.8% better than those of pwMS with primary progressive MS (PPMS) and 13.8% better than those of pwMS with secondary progressive MS (SPMS). For pwMS with SPMS, the dynamic MQ was 16.7% worse than that of patients with RRMS, while the power MQ was 29.5% worse. By degree of disability (<4 >7.5 EDSS score), patients with better MQ had mild EDSS scores, and patients with severe EDSS scores had 24.8%, 25.9%, and 40.3% worse isometric, dynamic, and power MQ scores, respectively, than those with RRMS. Based on these results, reference values for MQ in pwMS were established. Conclusions: The pwMS with different types of MS do not show differences in lean mass or strength but do show differences in MQ. In pwMS with different EDSS grades, there are no differences in lean mass, but there are differences in strength based on MQ, especially power MQ.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3