Safety and Performance of Titanium Suture Anchors Used in Knee Ligament Repair Procedures

Author:

Maestro Antonio,Pipa IvánORCID,Rodríguez Nicolás,Toyos Carmen,Torrontegui-Duarte MarcelinoORCID,Castaño Cesar

Abstract

Injuries to the knee ligaments can be particularly disabling in young patients, given the risk of long-term disability if adequate fixation is not achieved during initial repair. The TWINFIX™ titanium (Ti) suture anchor with ULTRABRAID™ Suture (Smith and Nephew, London, UK) was designed to secure tendon and ligament reconstructions with increased boney ingrowth at the anchor site with minimal invasive technique. This retrospective analysis looked at 33 patients (41 implants) operated with this device between 2015 and 2019 at a single institution. The average age of patients was 33.18 years (standard deviation [SD], 15.26), with an average body mass index of 24.88 (SD, 3.49). The indications were lateral extra-articular tenodesis during anterior cruciate ligament reconstruction, medial patellofemoral ligament reconstruction, quadriceps or patellar tendon repair and medial collateral ligament repair. After an average follow up of 24.3 + 6.53 months, there was no reports of clinical failure or radiographic evidence of implant failure or loosening. One patient experienced a complication unrelated to the study device, requiring manipulation under anesthesia with resolution of symptoms. This case series supports the safety and performance of this implants for the knee procedures in which its use is indicated. Additional follow-up will be required to determine whether these effects are sustained at medium- and long-term durations.

Publisher

MDPI AG

Subject

General Medicine

Reference23 articles.

1. Complete Rupture of the Triceps Tendon and Ulnar Collateral Ligament of the Elbow in a 13-Year-Old Football Player: A Case Report;Khalil;J. Orthop. Case Rep.,2018

2. Open patellar tendon avulsion from tibial tuberosity after ACL reconstruction successfully treated with suture anchors;Dario;Acta Biomed,2019

3. Arthroscopic Repair of Full-Thickness Tears of the Rotator Cuff in Patients Younger Than 40 Years

4. Assessments of activities of daily living after arthroscopic SLAP repair with knot-tying versus knotless suture anchors

5. Anterior talofibular ligament (ATFL) repair using two suture anchors produced better functional outcomes than using one suture anchor for the treatment of chronic lateral ankle instability

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3