Optimization of the “Perth CT” Protocol for Preoperative Planning and Postoperative Evaluation in Total Knee Arthroplasty

Author:

Stojadinović Milica1ORCID,Mašulović Dragan12,Kadija Marko23,Milovanović Darko23ORCID,Milić Nataša245,Marković Ksenija4,Ciraj-Bjelac Olivera67

Affiliation:

1. Center for Radiology, University Clinical Center of Serbia, Pasterova 2, 11000 Belgrade, Serbia

2. Faculty of Medicine, University of Belgrade, 11000 Belgrade, Serbia

3. Clinic for Orthopedic Surgery and Traumatology, University Clinical Center of Serbia, Pasterova 2, 11000 Belgrade, Serbia

4. Institute for Medical Statistic and Informatics, University Clinical Center of Serbia, Pasterova 2, 11000 Belgrade, Serbia

5. Department of Internal Medicine, Division of Nephrology and Hypertension, Mayo Clinic, Rochester, MN 55905, USA

6. Vinca Institute of Nuclear Sciences—National Institute of the Republic of Serbia, 11000 Belgrade, Serbia

7. Faculty of Electrical Engineering, University of Belgrade, 11000 Belgrade, Serbia

Abstract

Background and Objectives: Total knee arthroplasty (TKA) has become the treatment of choice for advanced osteoarthritis. The aim of this paper was to show the possibilities of optimizing the Perth CT protocol, which is highly effective for preoperative planning and postoperative assessment of alignment. Materials and Methods: The cross-sectional study comprised 16 patients for preoperative planning or postoperative evaluation of TKA. All patients were examined with the standard and optimized Perth CT protocol using advance techniques, including automatic exposure control (AEC), iterative image reconstruction (IR), as well as a single-energy projection-based metal artifact reduction algorithm for eliminating prosthesis artifacts. The effective radiation dose (E) was determined based on the dose report. Imaging quality is determined according to subjective and objective (values of signal to noise ratio (SdNR) and figure of merit (FOM)) criteria. Results: The effective radiation dose with the optimized protocol was significantly lower compared to the standard protocol (p < 0.001), while in patients with the knee prosthesis, E increased significantly less with the optimized protocol compared to the standard protocol. No significant difference was observed in the subjective evaluation of image quality between protocols (p > 0.05). Analyzing the objective criteria for image quality optimized protocols resulted in lower SdNR values and higher FOM values. No significant difference of image quality was determined using the SdNR and FOM as per the specified protocols and parts of extremities, and for the presence of prothesis. Conclusions: Retrospecting the ALARA (‘As Low As Reasonably Achievable’) principles, it is possible to optimize the Perth CT protocol by reducing the kV and mAs values and by changing the collimation and increasing the pitch factor. Advanced IR techniques were used in both protocols, and AEC was used in the optimized protocol. The effective dose of radiation can be reduced five times, and the image quality will be satisfactory.

Publisher

MDPI AG

Reference45 articles.

1. Interobserver Agreement of Post-operative Perth Computed Tomography Protocol Data in Total Knee Arthroplasty;Jones;Cureus,2023

2. Current variability in the assessment of component position for the unhappy knee replacement;Suchowersky;ANZ J. Surg.,2020

3. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030;Kurtz;J. Bone Jt. Surg. Am.,2007

4. Projected increase in total knee arthroplasty in the United States—An alternative projection model;Inacio;Osteoarthr. Cartil.,2017

5. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial;Chauhan;J. Bone Jt. Surg. Br.,2004