Influence of Torque on Platform Deformity of the Tri-Channel Implant: Two- and Three-Dimensional Analysis Using Micro-Computed Tomography

Author:

de Morais Renata Costa1,Simionato Anselmo Agostinho1ORCID,Moris Izabela Cristina Maurício2,Leoni Graziela Bianchi2,Faria Adriana Cláudia Lapria1,Rodrigues Renata Cristina Silveira1ORCID,Ribeiro Ricardo Faria1ORCID

Affiliation:

1. Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-904, Brazil

2. Department of Dentistry, Ribeirão Preto University—UNAERP, Ribeirão Preto 14096-900, Brazil

Abstract

Background and Objectives: The insertion of the dental implant in the bone is an essential step in prosthetic rehabilitation. The insertion torque has the potential to distort the prosthetic platform, which can cause future biomechanical problems with the continuous action of occlusal forces. The aim of this study is to evaluate different insertion torques in the deformation of tri-channel platform connections through two- and three-dimensional measurements with micro-CT. Materials and Methods: A total of 164 implants were divided into groups (platform diameter and type): 3.5, 3.75, and 4.3 mm NP (narrow platform), and 4.3 mm RP (regular platform). Each implant–platform group was then divided into four subgroups (n = 10) with different torques: T45 (45 Ncm), T80 (80 Ncm), T120 (120 Ncm), and T150 (150 Ncm). The implant–abutment–screw assemblies were scanned and the images obtained were analyzed. Results: A significant difference was observed for the linear and volume measures between the different platforms (p < 0.01) and the different implant insertion torques (p < 0.01). Qualitative analysis suggested a higher deformation resistance for the 3.75 NP compared to the 3.5 NP, and RP was more resistant compared to the NP. Conclusions: The 0.25 mm increment in the implant platform did not increase the resistance to the applied insertion torques; the 4.3 mm implant was significantly stronger compared to the 3.5 mm implant; and the proposed micro-CT analysis was considered valid for both the 2D and 3D analyses of micro-gaps, qualitatively and quantitatively.

Funder

São Paulo Research Foundation (FAPESP—São Paulo, Brazil), PhD Scholarship

PhD scholarship from the Agency for the High-Standard Promotion of Graduate Courses—CAPES, Brazil

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3