Abstract
In this article, the average power handling capability (APHC) of corrugated slow-wave transmission lines (SWTLs) is investigated. Firstly, the attenuation constants of conductor and dielectric are extracted by the multiline method. Secondly, the thermal resistance of corrugated SWTLs is analyzed based on the constant-angle model. To deal with the non-uniform corrugated structure of SWTLs, the concept of average heat-spreading width (AHSW) is introduced. Finally, the APHC of the corrugated SWTL is calculated using the attenuation constant and the thermal resistance. In addition, the APHC considering the temperature-dependent resistivity of metal conductor is also presented. For validation, the APHCs of SWTLs with different geometric parameters are evaluated. The results agree well with those obtained by the commercial software.
Funder
Guangdong Provincial Key-Field Research Program
National Natural Science Foundation of China
Science and Technology Commission of Shanghai Municipality
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献