The Natural History of Retinal Sensitivity Loss in Diabetic Macular Ischemia over One Year Evaluated by Microperimetry

Author:

Tsai Wei-Shan1ORCID,Thottarath Sridevi1,Gurudas Sarega1,Zhao Jinzhi2,Cheung Chui Ming Gemmy2ORCID,Yamaguchi Taffeta Ching Ning3,Giani Andrea3,Pearce Elizabeth3,Sivaprasad Sobha1ORCID

Affiliation:

1. Moorfields Clinical Research Facility, NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust, 162 City Road, London EC1V 2PD, UK

2. Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore

3. Boehringer Ingelheim, Binger Street 173, 55218 Ingelheim am Rhein, Germany

Abstract

Background/Objectives: This one-year prospective observational study, conducted at two centers, aimed to report the natural history of retinal sensitivity (RS) loss in diabetic macular ischemia (DMI). Methods: Patients with stable-treated proliferative diabetic retinopathy (PDR) were recruited if there was evidence of DMI on optical coherence tomography angiography, defined as a foveal avascular zone ≥ 0.5 mm2 or parafoveal capillary dropout ≥ 1 quadrant. The minimal visual acuity required for performing microperimetry (MP) was ≥54 Early Treatment Diabetic Retinopathy Study letters (Snellen equivalent 20/80). The overall RS (oRS) and pointwise sensitivity (PWS) within the 3 × 3 mm macula were assessed at baseline and twelve months. A value <25 decibels (dB) was defined as impaired RS, and a decrease of 2 and 7 dB was regarded as mild and severe loss, respectively. Results: A total of 88 patients (97 eyes) were included. No statistically significant MP changes were detected at one year. However, 10% of the cohort lost oRS ≥ 2 dB, and 73% lost ≥2 dB PWS in ≥5 loci, whereas 1% lost oRS ≥ 7 dB, and 4% lost ≥7 dB PWS in ≥5 loci. The foveola and temporal parafovea were the most vulnerable to severe RS loss. Compared to their counterpart, eyes with baseline oRS ≥ 25 dB had significantly more RS loss in the macula and superior parafovea (55% versus 32% and 53% versus 28%, both p = 0.01). Conclusions: Rather than oRS loss, ≥2 dB loss in PWS in ≥5 loci is a more feasible outcome measure for clinical trials in DMI.

Funder

Boehringer Ingelheim International GmbH

NIHR Moorfields Clinical Research Facility and Biomedical Research Centre

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3