Usefulness of PET/CT with Carbon-11-Labeled Methionine in the Diagnosis of Tertiary Hyperparathyroidism

Author:

Kołodziej MaciejORCID,Saracyn Marek,Lubas ArkadiuszORCID,Dziuk Mirosław,Durma Adam DanielORCID,Smoszna Jerzy,Zelichowski Grzegorz,Niemczyk Stanisław,Kamiński Grzegorz

Abstract

Introduction: Tertiary hyperparathyroidism (tHP) may develop in patients treated with hemodialysis or peritoneal dialysis. Parathyroidectomy may result in a significant reduction in the severity of symptoms. For the effective surgical treatment of hyperparathyroidism, proper localization of the parathyroid glands prior to surgery is essential. The sensitivity of scintigraphy in the diagnosis of tHP is lower than in the diagnosis of primary hyperparathyroidism. In recent years, positron emission tomography (PET/CT) has been gaining importance, usually as a complementary technique. Aim: The aim of this study was to determine the usefulness of PET/CT with [11C]MET in the preoperative localization diagnosis of patients with tertiary hyperparathyroidism caused by chronic kidney disease, in whom first-line diagnostic methods did not allow the localization of pathologically parathyroid glands. Material and methods: The study was conducted in a group of 19 adult patients with severe tHP who were resistant or intolerant to non-invasive treatment, with negative results of scintigraphy and ultrasonography of the neck. The study protocol included measurement of the concentration of calcium, phosphorus, and PTH in the blood serum and performing PET/CT with [11C]MET. Results: A positive result of PET/CT was obtained in 89.5% of the patients (17/19). Parathyroidectomy was performed in 52.9% of the patients (9/17) with positive results of PET/CT with [11C]MET, which were fully consistent with the results of the histopathological examinations of the removed parathyroid glands. On this basis, the sensitivity of PET/CT with [11C]MET in the preoperative localization diagnosis of patients with tHP was found to be 100%. Multiple lesions were visualized in 57.9% of the patients (11/19). Ectopic lesions were visualized in 21.1% of the patients (4/19). Conclusions: PET/CT with [11C]MET is a sensitive technique for the second-line preoperative imaging of parathyroid glands in patients with tertiary hyperparathyroidism in whom first-line examinations, such as ultrasound and scintigraphy, has failed.

Funder

Military Institute of Medicine-National Research Institute

Publisher

MDPI AG

Subject

Food Science,Nutrition and Dietetics

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3