Investigation of Calcium and Magnesium Removal by Donnan Dialysis According to the Doehlert Design for Softening Different Water Types

Author:

Marzouk-Trifi Ikhlass1,Baklouti Lassaad2ORCID,Dammak Lasâad3

Affiliation:

1. Laboratoire de Recherche Dessalement ET Traitement Des Eaux, Faculté Des Sciences de Tunis, Université de Tunis El Manar, Tunis 1068, Tunisia

2. Department of Chemistry, College of Sciences and Arts at ArRass, Qassim University, Arras 51921, Saudi Arabia

3. Université Paris-Est Créteil, CNRS, ICMPE, UMR 7182, 2 rue Henri Dunant, 94320 Thiais, France

Abstract

In this study, calcium and magnesium were removed from Tunisian dam, lake, and tap water using Donnan Dialysis (DD) according to the Doehlert design. Three cation-exchange membranes (CMV, CMX, and CMS) were used in a preliminary investigation to establish the upper and lower bounds of each parameter and to more precisely pinpoint the optimal value. The concentration of compensating sodium ions [Na+] in the receiver compartment, the concentration of calcium [Ca2+] and magnesium [Mg2+] in the feed compartment, and the membrane nature were the experimental parameters. The findings indicate that the CMV membrane offers the highest elimination rate of calcium and magnesium. The Full Factorial Design makes it possible to determine how the experimental factors affect the removal of calcium and magnesium by DD. All parameters used had a favorable impact on the response; however, the calcium and magnesium concentration were the most significant ones. The Doehlert design’s Response Surface Methodology (RSM) was used to determine the optimum conditions ([Mg2+] = 90 mg·L−1, [Ca2+] = 88 mg·L−1, [Na+] = 0.68 mol·L−1) allowing a 90.6% hardness removal rate with the CMV membrane. Finally, we used Donnan Dialysis to remove calcium and magnesium from the three different types of natural water: Dam, Lake, and Tap water. The results indicate that, when compared to lake water and tap water, the removal of calcium and magnesium from dam water is the best. This can be linked to the water matrix’s complexity. Therefore, using Donnan Dialysis to decrease natural waters hardness was revealed to be suitable.

Publisher

MDPI AG

Subject

Filtration and Separation,Chemical Engineering (miscellaneous),Process Chemistry and Technology

Reference61 articles.

1. Ben Abdallah, S. (2007). Agricultural Water Management, Proceedings of the A Workshop in Tunisia, National Academies Press.

2. World Health Organization (2009). Calcium and Magnesium in Drinking-Water: Public Health Significance, World Health Organization.

3. World Health Organization (2010). Hardness in Drinking-Water, World Health Organization.

4. Regulations for calcium, magnesium or hardness in drinking water in the European Union member states;Kozisek;Regul. Toxicol. Pharmacol.,2020

5. Ca2+ and Mg2+ present in hard waters enhance trihalomethane formation;Navalon;J. Hazard. Mater.,2009

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Electrodialysis Technology for Water Softening Regarding Water Equilibrium;Arabian Journal for Science and Engineering;2024-01-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3