Affiliation:
1. Institute of Particle Process Engineering, RPTU Kaiserslautern-Landau, Gottlieb-Daimler-Straße, 67653 Kaiserslautern, Germany
Abstract
The modified fouling index (MFI) is a crucial characteristic for assessing the fouling potential of reverse osmosis (RO) feed water. Although the MFI is widely used, the estimation time required for filtration and data evaluation is still relatively long. In this study, the relationship between the MFI and instantaneous spectroscopic extinction measurements was investigated. Since both measurements show a linear correlation with particle concentration, it was assumed that a change in the MFI can be detected by monitoring the optical density of the feed water. To prove this assumption, a test bench for a simultaneous measurement of the MFI and optical extinction was designed. Silica monospheres with sizes of 120 nm and 400 nm and mixtures of both fractions were added to purified tap water as model foulants. MFI filtration tests were performed with a standard 0.45 µm PES membrane, and a 0.1 µm PP membrane. Extinction measurements were carried out with a newly designed flow cell inside a UV–VIS spectrometer to get online information on the particle properties of the feed water, such as the particle concentration and mean particle size. The measurement results show that the extinction ratio of different light wavelengths, which should remain constant for a particulate system, independent of the number of particles, only persisted at higher particle concentrations. Nevertheless, a good correlation between extinction and MFI for different particle concentrations with restrictions towards the ratio of particle and pore size of the test membrane was found. These findings can be used for new sensory process monitoring systems, if the deficiencies can be overcome.
Funder
the Federal Ministry of Economic Affairs and Climate Action
Subject
Filtration and Separation,Chemical Engineering (miscellaneous),Process Chemistry and Technology
Reference40 articles.
1. Li, N.N., Fane, A.G., Ho, W.W., and Matsuura, T. (2008). Advanced Membrane Technology and Applications, Wiley. (AIChE-100).
2. Missimer, T.M., Jones, B., and Maliva, R.G. (2015). Environmental Science and Engineering: Intakes and Outfalls for Seawater Reverse-Osmosis Desalination Facilities: Innovations and Environmental Impacts, Springer International Publishing.
3. A review of reverse osmosis membrane fouling and control strategies;Jiang;Sci. Total Environ.,2017
4. Ruiz-García, A., Melián-Martel, N., and Nuez, I. (2017). Short Review on Predicting Fouling in RO Desalination. Membranes, 7.
5. (2014). Standard Test Method for Silt Density Index (SDI) of Water (Standard No. D4189-14).
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献