Effect of Acid Flow Rate, Membrane Surface Area, and Capture Solution on the Effectiveness of Suspended GPM Systems to Recover Ammonia

Author:

Soto-Herranz MaríaORCID,Sánchez-Báscones Mercedes,Antolín-Rodríguez Juan ManuelORCID,Vanotti Matías B.ORCID,Martín-Ramos PabloORCID

Abstract

Ammonia losses from manure pose serious problems for ecosystems and human and animal health. Gas-permeable membranes (GPMs) constitute a promising approach to address the challenge of reducing farm ammonia emissions and to attain the EU’s Clean Air Package goals. In this study, the effect of NH3-N concentration, membrane surface area, acid flux, and type of capture solution on ammonia recovery was investigated for a suspended GPM system through three experiments, in which ammonia was released from a synthetic solution (NH4Cl + NaHCO3 + allylthiourea). The effect of two surface areas (81.7 and 163.4 cm2) was first evaluated using three different synthetic N emitting concentrations (3000, 6000, and 12,000 mg NH3-N∙L−1) and keeping the flow of acidic solution (1N H2SO4) constant (0.8 L·h−1). A direct relationship was found between the amount of NH3 captured and the NH3-N concentration in the N-emitting solution, and between the amount of NH3 captured and the membrane surface area at the two lowest concentrations. Nonetheless, the use of a larger membrane surface barely improved ammonia capture at the highest concentration, pointing to the existence of other limiting factors. Hence, ammonia capture was then studied using different acid flow rates (0.8, 1.3, 1.6, and 2.1 L∙h−1) at a fixed N emitting concentration of 6000 mg NH3-N∙L−1 and a surface area of 122.5 cm2. A higher acid flow rate (0.8–2.1 L∙h−1) resulted in a substantial increase in ammonia absorption, from 165 to 262 mg of NH3∙d−1 over a 14-day period. Taking the parameters that led to the best results in experiments 1 and 2, different types of ammonia capture solutions (H2SO4, water and carbonated water) were finally compared under refrigeration conditions (at 2 °C). A high NH3 recovery (81% in 7 days), comparable to that obtained with the H2SO4 solution (88%), was attained when chilled water was used as the capture solution. The presented results point to the need to carefully optimize the emitter concentration, flow rate, and type of capture solution to maximize the effectiveness of suspended GPM systems, and suggest that chilled water may be used as an alternative to conventional acidic solutions, with associated savings.

Publisher

MDPI AG

Subject

Filtration and Separation,Chemical Engineering (miscellaneous),Process Chemistry and Technology

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3