Abstract
Serum creatinine is an important clinical marker for renal clearance. However, two conventional methods (Jaffe and enzymatic) are prone to interferences with organic compounds as compared to the standard method (isotope dilution–liquid chromatography–mass spectrometry) and can cause a significant negative bias. Perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) are two common perfluorochemicals (PFCs) that can easily be accumulated in humans. We aimed to verify whether this bias is the result of an accumulation of PFCs. The serum creatinine values of 124 hemodialysis patients were analyzed using the three methods. We also aimed to evaluate which biochemical parameters will influence the difference between the conventional methods and the standard method. We found that a significant underestimation occurred when using the conventional methods. Albumin is an independent factor associated with negative bias, but it loses this correlation after dialysis, likely due to the removal of protein-bound uremic toxins. PFOS can cause negative bias when using the enzymatic method. Furthermore, this linear correlation is more significant in patients who used polysulfone-based dialysis membranes, possibly due to the better clearance of other uremic toxins. The serum creatinine of uremic patients can be significantly underestimated when using conventional methods. PFCs, as well the type of dialysis membrane being used, can be influencing factors.
Funder
Taipei Veterans General Hospital
Taipei City Hospital
Subject
Filtration and Separation,Chemical Engineering (miscellaneous),Process Chemistry and Technology
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献