Comparison of Orbital Reconstructive Effect between Customized Orbital Implants Using Three-Dimensional Printed Templates and Conventional Manual-Bending Implants in Blowout Fracture Surgery

Author:

Kwon Min-Seo1,Shin Hyun Jin2ORCID

Affiliation:

1. School of Medicine, Konkuk University, Seoul 50529, Republic of Korea

2. Department of Ophthalmology, Research Institute of Medical Sciece, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul 50529, Republic of Korea

Abstract

The aim of the present study was to determine the orbital reconstructive effect of customized orbital implants using three-dimensional (3D) printed templates compared with conventional manual-bending implants using computed tomography (CT)-based orbital volume measurements. This retrospective study reviewed the medical records and 3D-CT images of 90 patients who underwent medial, inferior, or inferomedial orbital wall reconstruction. The selected patients were categorized into two groups: (1) the 3D group that underwent surgery using 3D-printed customized orbital implant templates and (2) the manual group that received a conventional manual technique to mold the implant. The volume discrepancy (VD) was obtained by subtracting the volume of the contralateral unaffected eye from that of the injured eye. Of the 90 patients, 33 and 57 were divided into the 3D and manual groups, respectively. The volumes on the contralateral unaffected side and on the pre- and postoperative injured sides were 22.5 ± 2.9, 23.7 ± 3.0, and 22.3 ± 2.8 cm3 (mean ± SD), respectively, in the 3D group, and 21.5 ± 2.5, 22.7 ± 2.8, and 21.2 ± 2.7 cm3 in the manual group. The postoperative VD did not differ between the 3D (–0.2 ± 0.3 cm3) and manual (–0.3 ± 0.9 cm3) groups (p = 0.794). The volume on the postoperative injured side did not differ significantly from that on the contralateral unaffected side in the 3D group, but these did differ significantly in the manual group. Postoperative VD also increased with the preoperative VD in the manual group (Pearson correlation coefficient = 0.548, p = 0.001), whereas there was no such association in the 3D group. The orbital volume restoration effect had superior surgical outcomes for large fractures using the customized orbital implant with 3D-printed templates compared with manual-bending implants.

Funder

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference28 articles.

1. Endoscopic approach to orbital blowout fracture repair;Strong;Otolaryngol.—Head Neck Surg.,2004

2. Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures;Metzger;Ophthalmology,2006

3. Orbital fractures: A review;Joseph;Clin. Ophthalmol.,2011

4. An analysis of pure blowout fractures and associated ocular symptoms;Shin;J. Craniofacial Surg.,2013

5. Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity;Gellrich;Plast. Reconstr. Surg.,2002

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3