Comparison of Laser-Sintered and Milled Patient-Specific Reconstruction Plates for Complications and Outcomes in Mandibular Defects—Comparative Analysis of a Single-Center Cohort

Author:

Hagmann Alexander1,Schappacher Robert2,Pietzka Sebastian34,Sakkas Andreas34ORCID,Scheurer Mario3ORCID,Schramm Alexander34,Wilde Frank34,Ebeling Marcel3

Affiliation:

1. Medical School, University Hospital Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany

2. Department of Oral and Plastic Maxillofacial Surgery, Marienhospital, Böheimstraße 37, 70199 Stuttgart, Germany

3. Department of Oral and Plastic Maxillofacial Surgery, Military Hospital Ulm, Academic Hospital of the University of Ulm, Oberer Eselsberg 40, 89081 Ulm, Germany

4. Department of Oral and Maxillofacial Surgery, University Hospital Ulm, Albert-Einstein-Allee 10, 89081 Ulm, Germany

Abstract

CAD/CAM-manufactured implants are increasingly becoming the standard in current therapy. The question of whether the manufacturing-related rougher surface of selective laser fusion plates compared to milled, smoother reconstruction plates leads to increased postoperative complications such as infections, plate exposure, and fistulas has not yet been determined. A retrospective analysis of 98 patients who underwent surgical treatment with either a selective laser fusion plate or a milled reconstruction plate at our hospital was performed. The only significant predictors of the revision risk were the operation time and use of antiresorptive medication. In the KLS Martin® group, the risk of revision decreased by approximately 20% for each additional hour by which the operation time was increased (OR = 0.81). In the Depuy Synthes® group, the risk of revision increased by approximately 11% with each additional hour of operative time (OR = 0.81 × 1.37 = 1.11). Both groups showed no significant differences in the number of necessary revision surgeries as well as inpatient complications. In summary, we can say that the assumption that additively manufactured reconstruction plates have a rougher surface due to selective laser melting and thus make plaque accumulation and revisions more likely has not been confirmed. Overall, it seems imperative to select further studies regarding the clinical outcome depending on the selected plate system.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3