Abstract
Volatile organic compounds (VOCs) emitted from building materials into the indoor air may cause discomfort associated with a perceptible chemical odour and may irritate the upper respiratory tract. Hence, it is vital to control indoor air pollution sources, such as interior finishing materials, including adhesives. The study involved carrying out a series of experimental tests of VOC emissions of 25 adhesives based on the ISO 16000 series standards. The research concerns three groups of construction adhesives with indoor applications, i.e., flooring (10), finishing walls and ceilings (6), and for other applications such as edge-gluing or gluing tiles or mirrors (9) differing in chemical composition. A series of temperature tests were carried out for a representative floor adhesive at selected temperatures: 25 °C, 35 °C and 45 °C. The theoretical correlation approach was adopted to characterise the relationship between the emission rate and temperature of selected chemical compounds.
Subject
General Materials Science
Reference35 articles.
1. Emission of Volatile Organic Compounds (VOCs) from Dispersion and Cementitious Waterproofing Products
2. Opinion of the ANSES Concerning Changes in the Method Used to Determine Indoor Air Guideline Values (IAGVs)
https://www.anses.fr/en/system/files/AIR2010sa0307RaEN.pdf
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献