Affiliation:
1. Comparative Orthopaedic Research Laboratory, Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin-Madison, Madison, WI 53706, USA
Abstract
Implant failure is common in small animal orthopedics, but risk factors are rarely reported. Our objective was to determine whether abnormal fracture healing was associated with implant failure after fracture fixation in dogs and cats in a consecutive series of cases. Thirty-seven client-owned animals (thirty-two dogs, five cats) diagnosed with implant failure after fracture treatment from January 2013–September 2018 were studied. Medical and radiographic records were retrospectively reviewed to identify patients that underwent fracture fixation using open reduction and internal fixation with subsequent radiographic evidence of implant failure. Area moment of inertia (AMI), plate working length, and bone screw density were determined. Implant failure was found in 39 fractures in 37 animals, representing 23% of fracture cases during the study period. Cases of implant failure were at increased risk of delayed union, malunion, or non-union (p < 0.0001). The most common cause of implant failure was loosening (54%); the second most common was plate failure that included low AMI locking plates (28%). Major complications found in 22/39 fractures (56%) were associated with delayed union (p < 0.01). Surgical revision was performed in 49% of implant failure cases. Complications were most frequently identified after treatment of humeral fractures (26%). We conclude mechanical failure of implants increases the risk for delayed or abnormal fracture healing and often requires revision surgery. Implant AMI should be considered during preoperative planning. Locking plates are associated with implant failure if plate bending stiffness is not sufficient, based on findings from this case series.
Subject
General Veterinary,Animal Science and Zoology
Reference32 articles.
1. Griffon, D., and Hamaide, A. (2016). Complications in Small Animal Surgery, Wiley Blackwell. [1st ed.].
2. Biomechanics of fracture fixation failure;Hulse;Vet. Clin. N. Am. Small. Anim. Pract.,1991
3. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate–rod fixation applied to experimentally induced gap fractures in canine femora;Goh;Am. J. Vet. Res.,2009
4. Area moment of inertia for comparison of implant cross-sectional geometry and bending stiffness;Muir;Vet. Comp. Orthop. Traumatol.,1995
5. Treatment of femoral and tibial fractures in puppies by elastic plate osteosynthesis. A review of 17 cases;Sarrau;Vet. Comp. Orthop. Traumatol.,2007
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献