Rationale and Design of a Wearable Cardiopulmonary Monitoring System for Improving the Efficiency of Critical Care Monitoring

Author:

Lee Jina1,Hwang You-Mi23ORCID,Park Sung-Min145ORCID

Affiliation:

1. Department of Convergence IT Engineering (CiTE), Pohang University of Science and Technology (POSTECH), Pohang 37673, Gyeongsangbuk-do, Republic of Korea

2. Department of Cardiology, St. Vincent’s Hospital, The Catholic University of Korea, Seoul 16247, Republic of Korea

3. Catholic Research Institute for Intractable Cardiovascular Disease (CRID), College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea

4. Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Gyeongsangbuk-do, Republic of Korea

5. Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Gyeongsangbuk-do, Republic of Korea

Abstract

Despite the recent development of wearable cardiopulmonary monitoring devices and their necessity in clinical settings, the evidence regarding their application in real-world intensive care units (ICUs) is limited. These devices have notable problems, such as inefficient manufacturing and cumbersome hardware for medical staff and patients. In this study, we propose a simplified cardiopulmonary monitoring system and present a protocol for a single-center prospective study to evaluate the efficacy of the proposed system compared with those from the conventional monitoring system. The system was designed to continuously measure electrocardiogram, respiration rate, and oxygen saturation in a stand-alone device with an intuitive data visualization platform and automatic data collection. The accuracy of the data measured from the proposed device will be pre-validated by comparing them with those from the reference device. Medical staff from the St. Vincent’s Hospital ICU will complete a five-point Likert-type scale questionnaire regarding their experience with conventional ICU monitoring systems. The result will be compared with the second questionnaire conducted after deploying the system. Since this is a study proposal paper, we do not have any data on this study yet. However, compared with the conventional patient monitoring system, the proposed device should be a promising method to relieve medical staff fatigue and that of the patients who must wear and attach the monitoring device for a long time.

Funder

The Postech-Catholic Biomedical Engineering Institut

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science