Advantages of Multiposition Scanning in Echocardiographic Assessment of the Severity of Discordant Aortic Stenosis

Author:

Golukhova Elena Zelikovna1,Slivneva Inessa Viktorovna2,Farulova Inga Yur’evna3,Skopin Ivan Ivanovich3,Marapov Damir Ildarovich4,Murysova Dar’ya Vladimirovna3,Pirushkina Yuliya Dmitrievna5,Volkovskaya Irina Vasilyevna6

Affiliation:

1. A.N. Bakulev National Medical Scientific Center for Cardiovascular Surgery, Ministry of Health of the Russian Federation, 121552 Moscow, Russia

2. Department of Cardiovascular and Comorbid Pathology, A.N. Bakulev National Medical Scientific Center for Cardiovascular Surgery, Ministry of Health of the Russian Federation, 121552 Moscow, Russia

3. Department of Reconstructive Surgery of Heart Valves and Coronary Arteries, A.N. Bakulev National Medical Research Center for Cardiovascular Surgery, Ministry of Health of the Russian Federation, 121552 Moscow, Russia

4. Department of Public Health, Economics and Health Care Management, Kazan State Medical Academy—Branch Campus of the Federal State Budgetary Educational Institution of Further Professional Education, Russian Medical Academy of Continuous Professional Education, Ministry of Healthcare of the Russian Federation, 420012 Kazan, Russia

5. Department of Cardiology and Functional Diagnostics, A.N. Bakulev National Medical Scientific Center for Cardiovascular Surgery, Ministry of Health of the Russian Federation, 121552 Moscow, Russia

6. Polyclinic Department of the Institute of Coronary and Vascular Surgery, A.N. Bakulev National Medical Scientific Center for Cardiovascular Surgery, Ministry of Health of the Russian Federation, 121552 Moscow, Russia

Abstract

Aim of the study: The aim of this study was to perform a comparative analysis of severity of discordant aortic stenosis (AS) assessment using multiposition scanning and the standard apical window. Materials and Methods: All patients (n = 104) underwent preoperative transthoracic echocardiography (TTE) and were ranked according to the degree of AS severity. The reproducibility feasibility of the right parasternal window (RPW) was 75.0% (n = 78). The mean age of the patients was 64 years, and 40 (51.3%) were female. In 25 cases, low gradients were identified from the apical window not corresponding to the visual structural changes in the aortic valve, or disagreement between the velocity and calculated parameters was detected. Patients were divided into two groups: concordant AS (n = 56; 71.8%) and discordant AS (n = 22; 28.2%). Three individuals were excluded from the discordant AS group due to the presence of moderate stenosis. Results: Based on the comparative analysis of transvalvular flow velocities obtained from multiposition scanning, the concordance group showed agreement between the velocity and calculated parameters. We observed an increase in the mean transvalvular pressure gradient (ΔPmean) and peak aortic jet velocity (Vmax), ΔPmean in 95.5% of patients, velocity time integral of transvalvular flow (VTI AV) in 90.9% of patients, and a decrease in aortic valve area (AVA) and indexed AVA in 90.9% of patients after applying RPW in all patients with discordant AS. The use of RPW allowed the reclassification of AS severity from discordant to concordant high-gradient AS in 88% of low-gradient AS cases. Conclusion: Underestimation of flow velocity and overestimation of AVA using the apical window may lead to misclassification of AS. The use of RPW helps to match the degree of AS severity with the velocity characteristics and reduce the number of low-gradient AS cases.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3