Magnetic Resonance Imaging for Assessment of Endodontic Instruments’ Precision during “L-Shaped” Model Root Canals Preparation

Author:

Olek Tomasz,Węglarz Władysław P.ORCID,Trzcionka AgataORCID,Dziedzic ArkadiuszORCID,Tanasiewicz Marta

Abstract

The purpose of the mechanical root canal preparation is to clean it and give it the right shape. The preparation should be carried out in a way that maintains the original curvature and initial orientation of the apical end. Insufficient root canal preparation may prevent effective chemical decontamination and obturation to the full working length. The study aims to evaluate the shaping ability and effectiveness of the NiTi rotary and reciprocating endodontic instruments, compared to standard hand files using magnetic resonance imaging based on spin echo. Material and methods: A comparative study of severely curved root canals’ shaping abilities using three NiTi systems and K-type hand files was performed, with 40 training “endo-blocks” presenting with “L-shaped” canal. The root canal topography and geometry “before” and “after” mechanical preparation obtained by the magnetic resonance imaging based on the spin echo was used. The main measurement was made using the RARE sequence, with slice thickness reduced to 100 micrometers. In order to improve the signal-to-noise ratio, NA = 25 was used. To minimize the measurement time, the field of view was limited to a cuboid 17 × 16 × 3 mm, with a resolution of 33 × 31 × 100 micrometers. Each 3D image consisted of 512 × 512 × 30 voxels. The imaging plane has been selected in such a way as to fully illustrate the course of curvature of the model root canal. For TR = 5 s and effective TE = 36 ms, TA was 1.5 h. Measurements were performed twice, before and after the preparation of endo-blocs with a selected type of endodontic tools. Results: The use of rotary NiTi instruments caused a substantial alteration in the curvature topography and angle of the canals and change in the curvature length. The substantial discrepancy was observed during the preparation of simulated root canals with the reciprocating instruments and the use of WaveOne files led to the largest volume variation. No dependence between the amount of material removed and the measured intracanal side was observed when NiTi instruments were used. Preparation with hand K-type files revealed a relationship between the measuring side and the amount of material removed, with the lower values obtained for the canals’ internal curvatures. Conclusions: All the studied endodontic instruments allow a safe preparation of curved root canals in simulating in vivo conditions. The abbreviation of original root canals topography does not seem to be significantly altered following mechanical preparation of simulated, severely curved root canals. The spin echo-based magnetic resonance imaging technique can be utilized for visualization of the internal topography of the root’s canals in vitro before and after their mechanical preparation in in vitro conditions. In the future, magnetic resonance microscopy may become a diagnostic tool supporting the work of a clinician.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3